Abstract

This paper proposes a coordinated control of the reactive power between the STATCOMs (static synchronous compensators) and the grid-side converters (GSC) of wind farms equipped with PMSGs (permanent-magnet synchronous generators), by which the voltage fluctuations at the PCC (point of common coupling) are mitigated in the steady state. In addition, the level of voltage sags is reduced during grid faults. To do this, the GSC and the STATCOM supply reactive power to the grid coordinately, where the GSCs are fully utilized to provide the reactive power for the grid prior to the STATCOM operation. For this, the GSC capability of delivering active and reactive power under variable wind speed conditions is analyzed in detail. In addition, the PCC voltage regulation of the power systems integrated with large wind farms are analyzed for short-term and long-term operations. With this coordinated control scheme, the low power capacity of STATCOMs can be used to achieve the low-voltage ride-through (LVRT) capability of the wind farms during grid faults. The effectiveness of the proposed strategy has been verified by PSCAD/EMTDC simulation results.

Keywords

References

  1. W. Qiao, R. G. Harley, and G. K. Venayagamoorthy, "Coordinated reactive power control of a large wind farm and a STATCOM using heuristic dynamic programming," IEEE Trans. Energy Convers., Vol. 24, No. 2, pp. 493-503, Jun. 2009. https://doi.org/10.1109/TEC.2008.2001456
  2. N. R. Ullah and T. Thiringer, "Variable speed wind turbines for power system stability enhancement," IEEE Trans. Energy Convers., Vol. 22, No. 1, pp. 52-60, Mar. 2007. https://doi.org/10.1109/TEC.2006.889625
  3. M. Tsili and S. Papathanassiou, "A review of grid code technical requirements for wind farms," IET Renew. Power. Gener., Vol. 3, No. 3, pp. 308-332, Sep. 2009. https://doi.org/10.1049/iet-rpg.2008.0070
  4. T. H. Nguyen and D. C. Lee, "Ride-through technique for PMSG wind turbine using energy storage systems", Journal of Power Electronics, Vol. 10, No. 6, pp. 733-738, Nov. 2010. https://doi.org/10.6113/JPE.2010.10.6.733
  5. T. H. Nguyen and D. C. Lee, "Advanced fault ride-through technique for PMSG wind turbine systems using line-side converter as STATCOM," IEEE Trans. Ind. Electron., Vol. 60, No. 7, pp. 2842-2850, Jul. 2013. https://doi.org/10.1109/TIE.2012.2229673
  6. G. Tapia, A. Tapia, and J. X. Ostolaza, "Proportionalintegral regulator-based approach to wind farm reactive power management for secondary voltage control," IEEE Trans. Energy Convers., Vol. 22, No. 2, pp. 488-498, Jun. 2007. https://doi.org/10.1109/TEC.2005.858058
  7. T. Ackermann, Ed., Wind power in power systems. West Sussex, U.K.: Willey, 2005.
  8. J. M. Carrasco, L. G. Franquelo, J. T. Bialasiewicz, E. Galvan, R. C. P. Guisado, M. A. M. Prats, J. I. Leon, and N. M. Alfonso, "Power-electronic systems for the grid integration of renewable energy sources: a survey," IEEE Trans. Ind. Electron., Vol. 53, No. 4, pp. 1002-1016, Aug. 2006. https://doi.org/10.1109/TIE.2006.878356
  9. S. Engelhardt, I. Erlich, C. Feltes, J. Kretschmann, and F. Shewarega, "Reactive power capability of wind turbines based on doubly fed induction generators," IEEE Trans. Energy Convers., Vol. 26, No. 1, pp. 364-372, Mar. 2011. https://doi.org/10.1109/TEC.2010.2081365
  10. R. G. de Almedia, E. D. Castronuouvo, and J. A. P. Lopes, "Optimum generation control in wind parks when carrying out system operator requests," IEEE Trans. Power Syst., Vol. 21, No. 2, pp. 718-725, May 2006. https://doi.org/10.1109/TPWRS.2005.861996
  11. F. D. Kanellos and N. D. Hatziargyriou, "Optimal control of variable speed wind turbines in islanded mode of operation," IEEE Trans. Energy Convers., Vol. 25, No. 4, pp. 1142-1151, Dec. 2010. https://doi.org/10.1109/TEC.2010.2048216
  12. G. Gerdes , and F. Santjer, "Power quality of wind turbines and their interaction with the grid", in Proc. Eur. Wind Energy Conf., 14-16, Thessaloniki, Greece, pp. 1152-1157, Oct. 1998.
  13. C. Han, A. Q. Huang, M. E. Baran, S. Bhattacharya, W. Litzenberger, L. Anderson, A. L. Johnson, and A. A. Edris, "STATCOM impact study on the integration of a large wind farm into a weak loop power system," IEEE Trans. Energy Convers., Vol. 23, No. 1, pp. 226-233, Mar. 2008. https://doi.org/10.1109/TEC.2006.888031
  14. M. Kayikci and J. V. Milanovic, "Reactive power control strategies for DFIG-based plants," IEEE Trans. Energy Convers., Vol. 22, No. 2, pp. 389-396, Jun. 2007. https://doi.org/10.1109/TEC.2006.874215
  15. N. R. Ullah, T. Thiringer, and D. Karlsson, "Voltage and transient stability support by wind farms complying with the E.ON netz grid code," IEEE Trans. Power Syst., Vol. 22, No. 4, pp. 1647-1656, Nov. 2007. https://doi.org/10.1109/TPWRS.2007.907523
  16. H. Xie, L. Angquist, and H. P. Nee, "Design study of a converter interface interconnecting energy storage with the DC link of a STATCOM," IEEE Trans. Power Del., Vol. 26, No. 4, pp. 2676-2686, Oct. 2011.
  17. M. N. Slepchenkov, K. M. Smedley, and J. Wen, "Hexagram-converter-based STATCOM for voltage support in fixed-speed wind turbine generation systems," IEEE Trans. Ind. Electron., Vol. 58, No. 4, pp. 1120-1131, Apr. 2011. https://doi.org/10.1109/TIE.2010.2052536
  18. M. M. Montazeri and D. Xu, "Coordination of DFIG and STATCOM in a power system," in Proceeding of IEEE ISIE, pp. 993-998, 2012.
  19. H. Amaris and M. Alonso, "Coordinated reactive power management in power networks with wind turbines and FACTS devices," Energy Convers. Manage., Vol. 52, pp. 2575-2586, 2011. https://doi.org/10.1016/j.enconman.2011.02.012
  20. A. M. Munoz, Power quality: mitigation technologies in a distributed environment, Springer, 2007, Chap. 7.
  21. Q. Song and W. Liu, "Control of a cascade STATCOM with star configuration under unbalanced conditions," IEEE Trans. Power Electron., Vol. 24, No. 1, pp. 45-58, Jan. 2009. https://doi.org/10.1109/TPEL.2008.2009172
  22. M. Molinas, J. A. Suul, and T. Undeland, "Low voltage ride-through of wind farms with cage generators: STATCOM versus SVC," IEEE Trans. Power Electron., Vol. 23, No. 3, pp. 1104-1117, May 2008. https://doi.org/10.1109/TPEL.2008.921169
  23. B. Gultekin and M. Ermis, "Cascaded multilevel converterbased transmission STATCOM: system design methodology and development of a 12 kV ${\pm}$12MVAr power stage," IEEE Trans. Power Electron., Vol. 28, No. 11, pp. 4930-4950, Nov. 2013. https://doi.org/10.1109/TPEL.2013.2238642
  24. Z. Chen, F. Blaabjerg, Y. Hu, "Stability improvement of wind turbine system by STATCOM," IEEE Ind. Electron., IECON 2006 - 32nd Annual Conference, pp. 4213-4218, Nov. 2006.
  25. P. Kundur, Power system stability and control, New York: McGraw-Hill, 1993.
  26. W. Hu, Z. Chen, Y. Wang, and Z. Wang, "Flicker mitigation by active power control of variable-speed wind turbines with full-scale back-to-back power converters," IEEE Trans. Energy Convers., Vol. 24, No. 3, pp. 640-649, Sep. 2009. https://doi.org/10.1109/TEC.2009.2015994
  27. N. G. Hingorani and L. Gyugyi, Understanding FACTS: Concept and Technology of Flexible AC Transmission Systems. New York: IEEE, 2000.

Cited by

  1. Advanced Pitch Angle Control Based on Fuzzy Logic for Variable-Speed Wind Turbine Systems vol.30, pp.2, 2015, https://doi.org/10.1109/TEC.2014.2379293
  2. Analysis and evaluation of current distortion for photovoltaic system with isolation transformer vol.8, pp.7, 2014, https://doi.org/10.1049/iet-rpg.2013.0393
  3. A comprehensive review of low voltage ride through capability strategies for the wind energy conversion systems vol.56, 2016, https://doi.org/10.1016/j.rser.2015.11.073
  4. Advanced Reactive Power Reserve Management Scheme to Enhance LVRT Capability vol.10, pp.10, 2017, https://doi.org/10.3390/en10101540