A Study on the Improvement of Evaluation Methods and Standards for Simulation Evaluation of Computed Tomography

전산화단층촬영용장치의 모의 평가를 통한 평가방법 및 평가기준의 개선방안에 관한 연구

  • Kim, Kyo-Tae (Dept. of Hybrid Medicine and Science, Inje University) ;
  • Heo, Ye-Ji (Dept. of Biomedical Engineering, Inje University) ;
  • Shin, Jung-Wook (Dept. of Biomedical Engineering, Inje University) ;
  • Noh, Si-Cheul (Dept. of Radiological Science, International University of Korea) ;
  • Jung, Bong-Jae (Dept. of Radiological Science, International University of Korea) ;
  • Kang, Sang-Sik (Dept. of Radiological Science, International University of Korea) ;
  • Nam, Sang-Hee (Dept. of Biomedical Engineering, Inje University) ;
  • Park, Ji-Koon (Dept. of Radiological Science, International University of Korea)
  • 김교태 (인제대학교 융합의과학) ;
  • 허예지 (인제대학교 의용공학과) ;
  • 신정욱 (인제대학교 의용공학과) ;
  • 노시철 (한국국제대학교 방사선학과) ;
  • 정봉재 (한국국제대학교 방사선학과) ;
  • 강상식 (한국국제대학교 방사선학과) ;
  • 남상희 (인제대학교 의용공학과) ;
  • 박지군 (한국국제대학교 방사선학과)
  • Received : 2013.09.17
  • Accepted : 2013.10.25
  • Published : 2013.10.30

Abstract

In foreign countries, the impotance of quality assurance (QA) is increasing, whereas QA evaluation standards are not established properly in Korea. Thus this study was conducted to suggest improved QA evaluation standards and methods by studying/comparing/analyzing the literature in both Korea and foreign countries and prove its suitability through simulated evaluation. result of research in south korea, much check list using the evaluation method subjective, the evaluation of accuracy and reproducibility is meausred in the number of missing. Therefore, attempts to present a clear reference evaluation and objective way to solve the problem, examined the accuracy and reproducibility and 10times of measurement. The results of the simulated evaluation satisfied both proposed evaluation standards and methods. However the QA evaluation standards and methods for the items that are implemented only in Korea and high-contrast spatial resolution could have been established. In this regard, there is a need of further studies on the establishment of QA evaluation standards and methods that suits Korean situation.

국외의 경우 의료기기의 품질보증(QA)의 중요성이 대두되고 있으나, 국내의 경우 품질보증 평가기준이 명확하게 제시되어 있지 않다. 이에 본 연구에서는 국내 외 문헌 조사 및 비교 및 분석을 통하여 개선된 새로운 품질보증 평가기준 및 평가방법을 제시하고자 하였으며, 모의 평가 수행을 통하여 적합성을 확인하였다. 국내의 문헌 조사 결과, 다수의 항목이 주관적인 평가 방법을 이용하고 있으며, 정확성 및 재현성 평가로는 부족한 횟수로 측정을 수행하고 있다. 따라서 문제점들을 해결하기 위하여 객관적인 평가 방법 및 명확한 기준을 제시하고자 하였으며, 측정 횟수를 10회로 하여 정확성 및 재현성에 대하여 고려하였다. 모의 평가 결과, 제시한 평가 기준 및 평가방법에 모두 만족하는 것을 확인하였다. 그러나 국내에서만 시행하고 있는 항목과 고대조도 공간분해능에 대해서는 적합한 평가 기준 및 평가 방법을 정립하지 못하였다. 차후 국내 실정에 맞게 정립 연구가 필요할 것으로 사료된다.

Keywords

References

  1. The Catholic University of Korea Industry-Academic Cooperation Foundation, "Study for Accreditation Program of Diagnostic X-ray system", National Institute of Food and Drug Safety Evaluation, 2010
  2. Korea Testing Laboratory, "A study on the mandatory application plan for the third edition of IEC 60601 standards series(General Standard, Collateral Standards, Particular Standards)", National Institute of Food and Drug Safety Evaluation, 2011
  3. "Legitimacy and Optimization Guidelines of Computed Tomography Radiology", Korea Food & Drug Administration, Radiation safety management series No.28, 2012
  4. Brix G, Nagel HD, Stamm G, Veit R, Lechel U, Griebel J, Galanski M, "Radiation exposure in multi-slice versus single-slice spiral CT: Results of a nationwide survey", Eur Radiol, 13:1979-1991, 2003 https://doi.org/10.1007/s00330-003-1883-y
  5. Wall BF, Hart D, "Revised radiation doses for typical x-ray examinations", Br J Radiol, 70:437-439, 1997 https://doi.org/10.1259/bjr.70.833.9227222
  6. "Evaluation and routine testing in medical imaging departments - part 2-6 : Constancy tests-X-ray equipment for computed tomography IEC 61223-2-6:1994", Food and Drug Administration, HSS, 2010
  7. Kyo-Tae Kim, et al, "A Study on the Improvement of Quality Assurance Testing Standards and Methods for Computed Tomography", The Korean Society Radiology Proceeding of 2013 Spring Conference, Vol 7, No. 1, pp. 61-66, 2013
  8. "Evaluation and routine testing in medical imaging departments - Part 2 - 6 : Constancy tests - X-ray equipment for computed tomography, KS C IEC 61223-2-6:2005", Korean Standards Association, 2005
  9. "Department of Community Health Radiation Safety Section Ionizing Radiation Rules, : Part 15. Computed tomography Installations 21CFR.1020.33-sec.1020.33", Food and Drug Administration, HSS, 2010
  10. Nicholas Joseph Jr. RT (R)(CT) BS, MS., Taffi Rose, BS, RT (R), "Online Radiography Continuing Education for Radiologic X ray Technologist", 1-800-370-0614,
  11. S. Jeff Shepard, Chairman, Pei-Jan Paul Lin, Co-Chairman, etc, "Quality Control in Diagnostic Radiology, AAPM Report no. 74", Report of Task Group #12, Diagnostic X-ray Imaging Committee, 2002
  12. "European Guidelines on Quality Criteria of Computed Tomography EUR 16262"
  13. "Evaluation and routine testing in medical imaging departments - part 2-6 : Constancy tests - X-ray Equipment for Computed Tomography, JIS Z 4752-2-6;2001", Japaness Standards Association, JSRT/JSA, 2001.

Cited by

  1. Evaluation of High Absorption Photoconductor for Application to Auto Exposure Control Sensor by Screen Printing Method vol.9, pp.2, 2015, https://doi.org/10.7742/jksr.2015.9.2.67
  2. A Base Study on the Constancy Quality Control Test and Clause of Diagnosis Radiation Equipment vol.8, pp.3, 2014, https://doi.org/10.7742/jksr.2014.8.3.105
  3. A Study on recognition for Medical radiation of health and non-health for radiation safety vol.18, pp.2, 2016, https://doi.org/10.12812/ksms.2016.18.2.93
  4. A Study about Amendment of Safety Control of Computed Tomography vol.7, pp.6, 2013, https://doi.org/10.7742/jksr.2013.7.6.383
  5. The Study on Design of Customized Radiation Protective Layer for Medical Radiation Dose Reduction vol.8, pp.6, 2014, https://doi.org/10.7742/jksr.2014.8.6.333
  6. 액상 실리콘과 금속화합물을 융합한 저선량 방사선 차폐 소재 개발을 위한 사전연구 vol.40, pp.3, 2013, https://doi.org/10.17946/jrst.2017.40.3.14