DOI QR코드

DOI QR Code

A Study on the Airtightness Performance of New Han-ok Bedrooms

신한옥 침실 공간의 기밀성능 평가 연구

  • 이주엽 (전남대학교 건축과학기술연구소) ;
  • 장현충 (전남대학교 대학원 건축공학과) ;
  • 이태강 (전남대학교 건축과학기술연구소) ;
  • 송민정 (전남대학교 건축과학기술연구소) ;
  • 김선우 (전남대학교 공과대학 건축학부)
  • Received : 2013.05.06
  • Accepted : 2013.06.24
  • Published : 2013.06.30

Abstract

The purpose of this study is to evaluate the airtightness performance of New Han-ok and to supply fundamental data for standards establishment. Air leakage testings were accomplished by means of blower door test in 26 bedrooms of 16 Han-oks located in Jeonnam happy villages. Followings are results. 1) Air change per hour at 50 Pa(ACH50) is located on 8.42~78.38. 2) No correlation between ACH50 and volumes, floor area, above grade surface area. 3) The more wood structural elements are exposed, attached spaces, wooden sliding and casement windows, the less airtightness performance. 4) An Airtightness with ACH50/20(NL, Normalized leakage) is located on 0.42~3.92 and building leakage class following F(4%), G(11%, sufficiently leaky, No need mechanical ventilation), H(4%, Need of cost-effective tightening), I(31%), J(50%) by a single-story house the normalized leakage of ASHRAE.

Keywords

References

  1. 권오현, 김진효, 김민휘, 석윤진, 정재원, "Blower Door를 이용한 국내 주거용 건물의 기밀도 실측 사례 분석", 대한건축학회 논문집. v.26권, n.7호(통권 261호), 2010.7
  2. 조재훈, "초고층 주거건물에서의 단위세대 기밀성능 측정 및 평가", 대한건축학회 논문집, v.26권, n.10호(통권 264호), 2010.10
  3. 윤종호, 박재완, 이광성, 백남춘, 신우철, "충청지역 단독주택의 기밀성능 실측 연구", 한국태양에너지학회 논문집, Vol.28, No.5, 2008
  4. 신우철, 윤종호, 백남춘, "고기밀 고단열 주택의 기밀성능에 관한 실험적 연구", 한국태양에너지학회 논문집, Vol.25, No.4, 2005
  5. 이승복, 이윤규, "Blower Door를 이용한 건물의 기밀성능 측정 및 평가방법", 한국태양에너지학회 학술발표대회 논문집 1, 1994, pp.9-16
  6. 이주엽, 송민정, 이태강, 김선우, "한옥 구성 부재의 차음성능 평가에 관한 실험적 연구", 한국소음진동공학회 추계학술발표대회, 2012.10
  7. KS L ISO 9972:2006 단열-건물 기밀성 측정-팬가압법, 한국표준협회
  8. ISO 9972 Thermal Performance od Buildings - Determination of air permeability of buildings - Fan pressurization method, 2006
  9. The Energy Conservatory, Minneapolis Blower Door Operation Manual for Model 3 and Model 4 Systems. The Energy Conservatory, 2010.
  10. ASTM E 779:10 Standard Test Method for Determining Air Leakage Rate by Fan Pressurization
  11. ASHRAE Standard 119-1988, Air Leakage Performance for Detached Single Family Residential Buildings, 1998 (Withdrawn Standard(Updated February 2013), Withdrawn 2/17/2012, Standard 119 requirements were placed in Std 62.2)
  12. ANSI/ASHRAE Standard 62.2-2004, Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings, American Society of Heating Refrigerating and Air Conditioning, Engineers, Inc., Atlanta, GA
  13. Max H. Sherman, The Use of Blower Door Data, LBL Report No. 35173, 1998.03
  14. Alan Mier, Infiltration : Just ACH50 Divided by 20?, Home Energy Magazine, 1994
  15. CGSB Standard 149.15(1996), Determination of the overall enveloped air-tightness of buildings by the fan pressurizati on method using the building's air handling system, Canadian General Standards Board.
  16. KS F 2829:2005 적외선 촬영법에 의한 건축물 단열 성능 평가 방법, 한국표준협회

Cited by

  1. The atmospheric environmental impact of a Korean traditional building’s life cycle, along with carbon footprint analysis vol.28, 2017, https://doi.org/10.1016/j.scs.2016.09.008