Behavior Characteristics of Water Supply Pipeline Due to Freezing Temperature

동결온도가 상수도관의 거동에 미치는 영향

  • Shin, Eun Chul (Dept. of SOC Research Institute, Korea Institute of Construction Technology) ;
  • Ryu, Byung Hyun (Dept. of SOC Research Institute, Korea Institute of Construction Technology) ;
  • Kang, Hyoun Hoi (Dept. of Civil and Environmental Engineering, Incheon National University) ;
  • Hwnag, Soon Gab (Dept. of Civil and Environmental Engineering, Incheon National University)
  • Received : 2014.05.29
  • Accepted : 2014.10.22
  • Published : 2014.12.30

Abstract

This paper presents the results of a field pilot test about deformation of water supply pipelines due to freezing temperature. There is a difference between for frost heaving load to act on the water supply pipelines. If the Marston-Spangler theory is only considered for the frost heaving load to act on the water supply pipeline, it is likely to deviate from the safety of the water supply pipeline, strains of the water supply pipeline show a tendency of smaller value than the value of numerical analysis.

이 논문에서는 현장모형 실험을 통하여 동결온도에 따른 상수도관의 거동변형특성을 다루었다. 동결 온도 조건에 따라 상수도관에 미치는 동상압력과 Marston-Spangler 이론에 의한 동상 압력은 다소 차이를 나타내는 것을 보이며, Marston-Spangler이론만으로 관에 작용하는 하중을 고려하는 것은 안전측을 벗어날 수도 있다는 것을 염두 해야 한다. 또한 현장모형실험을 통한 상수도관의 변형률은 수치해석결과보다 작은 값을 나타내는 것을 확인하였다.

Keywords

References

  1. Argue, G. and Denyes., (1974), Estimating the Depth of Pavement Frost and Thaw Penetrations, Transportation Research Record, Volume 497, pp.18-30.
  2. Akagawa, S. (1985), "Frost Heave Characteristics and scale effect of Stationary Frost Heave", Fourth International Symposium on Ground Freezing, Sapporo, pp.137-143.
  3. Orlando, B., Andersland, D. B., Ladanyi, B. (1994), An Introduction to Frozen Ground Engineering, Chapman Hall, pp.8-61.
  4. Hoeksta, P. (1966), Moisture Movement in Soils Under Temperature Gradients with The Cold-side Temperature Blow Freezing, Water Resource, Research, Vol.2, pp.241-250. https://doi.org/10.1029/WR002i002p00241
  5. Kim, Y. C., Yu, J., Kim, H. M. (1999), A Study on the Frost penetration Depth and Insulation methods in pavement, Korea Institute of Construction Technology Reaserch Report, pp.5-25.
  6. Kim, Y. H. (1998), "Incorporating climate Change scenarios into Water Resources management", Journal of Korea Water Resources Association, Vol 13, No.4, pp.407-413.
  7. Konrad, J., Mogenstern, N. (1982), "Prediction of Frost Heaving in the Laboratory during Transient Freezing", Canadian Geotech. Jounal, Vol.19, pp.250-259. https://doi.org/10.1139/t82-032
  8. Marston A. and Anderson, A. (1913), "The Theory of Loads on Pipes in Ditches and Test of Cement and Clay Drain tile and Sewer Pipe", Iowa Engineering, Iowa, No.31, pp.181.
  9. Park, S. W., Do, J. N., Jung J. J., Chun, B. S. (2008), "Vertical Earth Pressure on Buried pipes in Ditches due to Fills", Jounal Korean Geo-Environmental society, Vol.9 No.1, pp.11-16.
  10. Ryu, B. H. (2013), Deformation Factors and Behavior Characteristics of the Water Supply Pipeline During Ground Freezing, In Korean, Ph.D Thesis, Incheon National University, pp.24-25.
  11. Taber, S. (1929), Frost heaving, J. Geol. 37, pp.428-461. https://doi.org/10.1086/623637
  12. Tice, A., Burrous, C., and Anderson, D. (1978), "Phase Composition Measurement on Soil at Very High Water Contents by the Pulsed Nuclear Magnetic Resonance Technique", Presented at Trans. Res. Board Meeting, Washington, D. C., pp.16-20.
  13. Yong, R., Warkentin, B. (1975), Soil Properties and Behaviour, Elsevier Scientific Publishing Company, Amsterdam, pp.383-419.