DOI QR코드

DOI QR Code

Study on a Forward Light Changes According to the Surface Treatment of Light Cutoff Panel

차광판 표면 처리 방법에 따른 전사광 변화에 관한 연구

  • Received : 2014.09.05
  • Accepted : 2014.10.01
  • Published : 2014.12.31

Abstract

Since the "Light Pollution Prevention Act" was executed, the installation of the light cutoff panel to the security lightings which caused light trespass has been increased in the local government. The light cutoff panel is effective in reducing the light trespass in term of the cost-benefit. Because the installation of the light cutoff panel is inexpensive than the change of the security lighting. But the reflected light from the surface of the light cutoff panel has been regarded as another light pollution problem to solve. Therefore, we try to improve light cutoff panel by changing the light reflectivity characteristic of the surface of the light cutoff panel. First, we laminated the surface of light cutoff panel by black powder to reduce the light reflectivity of the light cutoff panel. After the black powder lamination, the light reflectivity on the light cutoff panel improved from 85% to 5%. And we compared reflected light caused by black powder laminated light cutoff panel with the one of no surface treatment cutoff panel. The vertical illuminance was measured at 3, 6, 9m in front of the security lighting and 3, 6, 9, 12, 15, 18m in back of the security lighting to evaluate the reflected light. And the measurement height was determined of 1.5m considering the height of the 1th floor of an apartment house. In this study, we found that the reflected light from the light cutoff panel can be reduced about 90% by the black powder lamination method. The results derived from this study will be helpful to develope the various kind of light cutoff panel which minimize the adverse effect like reflected light of light cutoff panel.

Keywords

References

  1. Ministry of environment "Act on Prevention of Light Pollution Caused by Artificial Lightings", 2013.2
  2. Han, S. H., Gu, J. H., Lee, Y. G., "Research on effect of installing light shield of existing security lights for preventive measures for light pollution", Journal of the Korean Institute of Illuminating and electrical Installation Engineers, 28(3), pp.7-13, 2014. https://doi.org/10.5207/JIEIE.2014.28.3.007
  3. Gu, J., Jung, J. H., Lee, K., "Research on the Characteristics of the Light Trespass using by RELUX Program According to the Spatial Position of the Road Lightings in Residential Area Near Road", Journal of the Korean Institute of Illuminating and electrical Installation Engineers, 26(11), pp.1-8, 2012. https://doi.org/10.5207/JIEIE.2012.26.11.001