DOI QR코드

DOI QR Code

Analysis of Discomfort Glare by luminous intensity distribution of Marine Indoor Luminaires

선박용 실내조명기구의 배광에 따른 불쾌글레어 분석

  • Cho, Sang-Hee (Pukyoung National University LED-Marine Convergence Technology R&BD Center) ;
  • Kim, Kun-Yul (Pukyoung National University LED-Marine Convergence Technology R&BD Center) ;
  • Yu, Young-Moon (Pukyoung National University LED-Marine Convergence Technology R&BD Center)
  • 조상희 (부경대학교 LED-해양 융합기술 연구센터) ;
  • 김근율 (부경대학교 LED-해양 융합기술 연구센터) ;
  • 유영문 (부경대학교 LED-해양 융합기술 연구센터)
  • Received : 2014.01.13
  • Accepted : 2014.03.10
  • Published : 2014.03.31

Abstract

In this paper, tried to find out the proper luminous intensity distribution for the cabin with low-level height by analyzing the changing tendency of discomfort glare according to luminous intensity distribution of marine indoor luminaires using Unified Glare Rating(UGR). First, we analyzed UGR of the indoor luminaires in the existing cabin, and then evaluated influence on luminous intensity distributions of marine indoor luminaire. The results showed that $cos^2{\Theta}$ distribution got almost low UGR results regardless of height and UGR 16.5 in cabin height of 2m. However, Gaussian distribution with the same beam angle showed that UGR results consistently increased by getting lower height and UGR 20.7 in the same height. In conclusion, the $cos^2{\Theta}$ distribution in consideration of luminous intensity on the direction of observer's eye was appropriate for general cabin indoor luminaires because it decreased UGR in the low-level height.

Keywords

References

  1. S.-R.Park, Evaluation of discomfort glare from non-uniform luminance distribution windows, Department architectural engineering the graduate school, Kyunghee university, 2009.
  2. CIE 117, "DISCOMFORT GLARE IN INTERIOR LIGHTING", 1995.
  3. Michelle L. Eble-Hankins PE. LC, and Clarence E. Waters, PhD, PE, VCP and UGR Glare Evaluation System:A Look Back and a way Forward, LEUKOS VOL 1 No. 2, pp 7-38.
  4. S.-R.Park,W.-W.Kim, J.-T.Kim, Effect of background luminance on the evaluation of discomfort glare from large and small light sources, Architectural Institute of Korea, Vol.25, No.3, 2009.03.
  5. "Discomfort glare in interior lighting" Collective standard, Journal of the Korean Institute of Illuminating and Electrical Installation Engineers, 2009.12.
  6. A.-S.Choi, A study on the comparison of discomfort glare evaluation systems, Architectural Institute of Korea, Vol.17, No.6, 2001.06.
  7. Y.-S.Kim, A.-S.Choi, Analysis of the change of intensity distribution and luminous environment by reflector shape in indirect reflected LED luminaires, Journal of the Korean Institute of Illuminating and Electrical Installation Engineers, Vol.25, No.1, pp. 9-17, 2011.01. https://doi.org/10.5207/JIEIE.2011.25.1.009
  8. IESNA RP 12-97, "Marine Lighting", Table 3. Illuminance levels for marine lighting tasks, 1997.
  9. ISO 8995 CIE S008/E Second edition "LIGHTING OF INDOOR WORK PLACES", 2002.