DOI QR코드

DOI QR Code

The comparative study of user satisfaction on various implant engine system

다양한 임플란트 엔진 시스템에 대한 사용자 만족도 비교

  • Lee, Du-Hyeong (Department of Prosthodontics, School of Dentistry, Kyungpook National University) ;
  • Lee, Kyu-Bok (Department of Prosthodontics, School of Dentistry, Kyungpook National University)
  • 이두형 (경북대학교 치과대학 치과보철학교실) ;
  • 이규복 (경북대학교 치과대학 치과보철학교실)
  • Received : 2013.12.05
  • Accepted : 2014.03.08
  • Published : 2014.03.31

Abstract

Purpose: Implant engine system is composed of the handpiece, micromotor, control box and foot switch. The aim of this study was to evaluate the satisfaction of the implant engine systems in terms of convenience-design and to examine the relation with the experience of implant surgery. Materials and Methods: Three implant systems were evaluated: SurgicXT/X-SG20L, INTRAsurg300/CL3-09, XIP10/CRB26LX. For this comparative study, 30 dentists were included and the satisfaction was measured using a structured questionnaire. One-way analysis of the variance (ANOVA) and multiple regression analysis were used within and between the groups. Results: Total satisfaction differed from each other (P < 0.05). The convenience score was more associated with the total satisfaction than design score. Moreover, the implant surgery experience affected several assessments. Conclusion: Collectively, in a cross-sectional study model, the design of implant system significantly affects its total satisfaction and the surgery experience can be influential factor in the evaluation of implant engine system.

목적: 임플란트 엔진 시스템은 임플란트 시술 과정에서 사용하며 핸드피스, 구동모터, 본체, 그리고 풋스위치로 구성되어 있다. 본 연구의 목적은 임플란트 엔진 시스템의 편의성, 디자인 그리고 전체 만족도를 평가하고, 임플란트 식립 경험와 평가와의 관련성을 조사하고자 하였다. 연구 재료 및 방법: 총 30명의 치과의사를 대상으로 구조화된 설문지를 통해 3개 제조사의 시스템(NSK 의 SurgicXT와 X-SG20L, KaVo의 INTRAsurg300와 CL3-09, Saeshin의 XIP10와 CRB26LX)의 편의성, 디자인, 만족도를 비교 연구의 방식으로 조사하였다. 통계분석은 일원배치 분산분석과 중회귀분석을 이용하였다. 결과: 전체 만족도는 각기 다르게 나타났고(P < 0.05), 전체 만족도에는 편의성 평가가 디자인 평가보다 더 큰 영향을 미쳤다. 임플란트 수술 경험의 정도와 일부 영역의 평가와는 관련이 있었다. 결론: 임플란트 엔진 시스템의 횡단적 단면 평가 시에 디자인이 전체 만족도에 영향을 미치고, 임플란트 식립 횟수는 평가 시 영향력 있는 인자가 될 수 있음을 관찰할 수 있었다.

Keywords

References

  1. Grochulla F, Vieweg U. Surgical motor systems in spinal surgery. In: Vieweg U, Grochulla F, editors. Manual of spine surgery. Berlin; Springer Berlin Heidelberg; 2012. p. 69-74.
  2. Campbell SC. Are friends electric?: a review of the electric handpiece in clinical dental practice. Dent Update 2013;40:194-6, 199-200. https://doi.org/10.12968/denu.2013.40.3.194
  3. Christensen GJ. Are electric handpieces an improvement? J Am Dent Assoc 2002;133:1433-4. https://doi.org/10.14219/jada.archive.2002.0061
  4. Ercoli C, Rotella M, Funkenbusch PD, Russell S, Feng C. In vitro comparison of the cutting efficiency and temperature production of ten different rotary cutting instruments. Part II: electric handpiece and comparison with turbine. J Prosthet Dent 2009;101:319-31. https://doi.org/10.1016/S0022-3913(09)60064-0
  5. Kenyon BJ, Van Zyl I, Louie KG. Comparison of cavity preparation quality using an electric motor handpiece and an air turbine dental handpiece. J Am Dent Assoc 2005;136:1101-5. https://doi.org/10.14219/jada.archive.2005.0313
  6. Uicker JJ, Pennock GR, Shigley JE. Theory of machines and mechanisms. 3rd ed. New York; Oxford University Press; 2003. p. 252-70.
  7. International Ergonomics Association. Definition and domains of ergonomics. Available from: http://www.iea.cc/whats/index.html (updated 2013 Dec 5).
  8. Yoon JG. Who do UI designers work for?. IDCC Proceeding 2007;7:33-41.
  9. Gupta A, Ankola AV, Hebbal M. Dental ergonomics to combat musculoskeletal disorders: a review. Int J Occup Saf Ergon 2013;19:561-71. https://doi.org/10.1080/10803548.2013.11077005
  10. Nkenke E, Vairaktaris E, Bauersachs A, Eitner S, Budach A, Knipfer C, Stelzle F. Acceptance of virtual dental implant planning software in an undergraduate curriculum: a pilot study. BMC Med Educ 2012;12:90. https://doi.org/10.1186/1472-6920-12-90
  11. Lijphart A. II. The comparable-cases strategy in comparative research. Comparative Political Studies 1975;8:158-77. https://doi.org/10.1177/001041407500800203

Cited by

  1. 컴퓨터 단층 촬영을 기반으로 한 임플란트 가이드 시스템에 대한 임상가의 만족도 분석 vol.31, pp.3, 2014, https://doi.org/10.14368/jdras.2015.31.3.178
  2. A comparative study on the user satisfaction between two different piezoelectric engines vol.33, pp.4, 2014, https://doi.org/10.14368/jdras.2017.33.4.269