DOI QR코드

DOI QR Code

Vibration control of high-rise buildings for wind: a robust passive and active tuned mass damper

  • Aly, Aly Mousaad (Department of Civil and Environmental Engineering, Louisiana State University)
  • Received : 2012.07.03
  • Accepted : 2013.07.05
  • Published : 2014.03.25

Abstract

Tuned mass dampers (TMDs) have been installed in many high-rise buildings, to improve their resiliency under dynamic loads. However, high-rise buildings may experience natural frequency changes under ambient temperature fluctuations, extreme wind loads and relative humidity variations. This makes the design of a TMD challenging and may lead to a detuned scenario, which can reduce significantly the performance. To alleviate this problem, the current paper presents a proposed approach for the design of a robust and efficient TMD. The approach accounts for the uncertain natural frequency, the optimization objective and the input excitation. The study shows that robust design parameters can be different from the optimal parameters. Nevertheless, predetermined optimal parameters are useful to attain design robustness. A case study of a high-rise building is executed. The TMD designed with the proposed approach showed its robustness and effectiveness in reducing the responses of high-rise buildings under multidirectional wind. The case study represents an engineered design that is instructive. The results show that shear buildings may be controlled with less effort than cantilever buildings. Structural control performance in high-rise buildings may depend on the shape of the building, hence the flow patterns, as well as the wind direction angle. To further increase the performance of the robust TMD in one lateral direction, active control using LQG and fuzzy logic controllers was carried out. The performance of the controllers is remarkable in enhancing the response reduction. In addition, the fuzzy logic controller may be more robust than the LQG controller.

Keywords

References

  1. Aldawod, M., Samali, B., Naghdy, F. and Kwok K.C.S. (2001), "Active control of along wind response of tall building using a fuzzy controller", Eng. Struct., 23(11), 1512-1522. https://doi.org/10.1016/S0141-0296(01)00037-2
  2. Aly, A.M. (2009), On the dynamics of buildings under winds and earthquakes: response prediction and reduction, Ph.D. Dissertation, Politecnico di Milano, Milan, Italy.
  3. Aly, A.M. and Christenson. R.E. (2008), "On the evaluation of the efficacy of a smart damper: a new equivalent energy-based probabilistic approach", Smart Mater. Struct., 17(4), Article ID: 045008.
  4. Aly, A.M., Zasso, A. and Resta, F. (2012), "Proposed configurations for the use of smart dampers with bracings in tall buildings", Smart Mater. Res., Article ID: 251543. Doi:10.1155/2012/251543.
  5. Aly, A.M. (2012), "Proposed robust tuned mass damper for response mitigation in buildings exposed to multidirectional wind", Struct. Des. Tall Spec., DOI: 10.1002/tal.1068.
  6. Aly, A.M., Zasso, A. and Resta, F. (2011a), "On the dynamics of a very slender building under winds: response reduction using MR dampers with lever mechanism", Struct. Des. Tall Spec., 20(5), 539-551. Doi: 10.1002/tal.647.
  7. Aly, A.M., Zasso, A. and Resta, F. (2011b), "Dynamics and control of high-rise buildings under multidirectional wind loads", Smart Mater. Res., Article ID: 549621. Doi:10.1155/2011/549621.
  8. Aly, A.M., Resta, F. and Zasso, A. (2008), "Active control in a high-rise building under multidirectional wind loads", Proceedings of the 2008 Structures Congress - Structures Congress 2008: Crossing the Borders, American Society of Civil Engineers, Vancouver, BC, Canada, April 24-26. Doi: 10.1061/41016(314)285.
  9. Attaway, S. (2009), Matlab: A practical introduction to programming and problem solving, Butterworth-Heinemann, Amsterdam, Netherlands.
  10. Bani-Hani, K.A. (2007), "Vibration control of wind-induced response of tall buildings with an active tuned mass damper using neural networks", Struct. Control. Health Monit., 14(1), 83-108. https://doi.org/10.1002/stc.85
  11. Battaini, M., Casciati, F. and Faravelli, L. (1998), "Control algorithm and sensor location", Proceedings of the 2nd World Conf. on Structural Control, Kyoto, Japan, 28 June - 1 July.
  12. Bendat, J.S. and Piersol, A.G. (2000), Random data analysis and measurement procedures, 3rd Ed, Wiley Series in Probability and Statistics, New York, USA.
  13. Casciati, F. (1997), "Checking the stability of a fuzzy controller for nonlinear structures", J. Microcomput. Civ. Eng., 12(3), 205-215. https://doi.org/10.1111/0885-9507.00057
  14. Chowdhury, I. and Dasgupta, S. (2003), "Computation of Rayleigh damping coefficients for large systems", The Electronic Journal of Geotechnical Engineering, 8, Bundle 8C.
  15. Clinton, J.F., Bradford, C.S., Heaton, T.H. and Favela, J. (2006), "The observed wander of the natural frequencies in a structure", Bull Seismol. Soc. Amer., 96(1), 237-57. https://doi.org/10.1785/0120050052
  16. Davison, E.J. (1966), "A method for simplifying linear dynamic systems", IEEE T. Automat. Contr., 11(1), 93-101. https://doi.org/10.1109/TAC.1966.1098264
  17. Dyke, S.J., Caicedo, J.M., Turan, G., Bergman, L.A. and Hague S. (2003), "Phase I benchmark control problem for seismic response of cable-stayed bridges", J. Struct. Eng., 129(7), 857-872. https://doi.org/10.1061/(ASCE)0733-9445(2003)129:7(857)
  18. Eurocode 1. (2004), Eurocode 1: Actions on structures - General actions - Part 1-4: Wind actions. prEN 1991-1-4: European Standard.
  19. Feng, M.Q. and Mita, A. (1995), "Vibration control of tall buildings using mega subconfiguration", J. Eng. Mech. - ASCE, 121(10), 1082-1088. https://doi.org/10.1061/(ASCE)0733-9399(1995)121:10(1082)
  20. Ghorbani-Tanha, A.K., Noorzad, A. and Rahimian, M. (2009), "Mitigation of wind-induced motion of Milad tower by tuned mass damper", Struct. Des. Tall Spec., 18, 371-385. Doi: 10.1002/tal.421.
  21. Gu, M. and Peng, F.J. (2002), "An experimental study of active control of wind-induced vibration of super-tall buildings", J. Wind Eng. Ind. Aerod., 90(12-15), 1919-1931. https://doi.org/10.1016/S0167-6105(02)00298-2
  22. Lee, J.J., and Yun, C.B. (2006), "Damage diagnosis of steel girder bridges using ambient vibration data", Eng. Struct. , 28(6), 912-925. https://doi.org/10.1016/j.engstruct.2005.10.017
  23. Li, C., Li, J. and Qu, J. (2010), "An optimum design methodology of active tuned mass damper for asymmetric structures", Mech. Syst. Signal Pr., 24(3), 746-765. https://doi.org/10.1016/j.ymssp.2009.09.011
  24. Li, C. and Zhu, B. (2006), "Estimating double tuned mass dampers for structures underground acceleration using a novel optimum criterion", J. Sound Vib., 298(1-2), 280-297. https://doi.org/10.1016/j.jsv.2006.05.018
  25. Li, Q.S., Yang, K., Zhang, N., Wong, C.K. and Jeary, A.P. (2002), "Field measurement of amplitude dependent damping in a 79-storey tall building and its effects on the structural dynamic responses", Struct. Des. Tall Spec., 11, 129-153.
  26. Liu, C. and DeWolf, J.T. (2007), "Effect of temperature on modal variability of a curved concrete bridge under ambient loads", J. Struct. Eng., 133(12), 1742-1751. https://doi.org/10.1061/(ASCE)0733-9445(2007)133:12(1742)
  27. Lu, L., Chiang, W., Tang, J., Liu, M. and Chen, C. (2003), "Active control for a benchmark building under wind excitations", J. Wind Eng. Ind. Aerod., 91(4), 469-493. Doi: 10.1016/S0167-6105(02)00431-2.
  28. Lu, X., Li, P., Guo, X., Shi, W. and Liu, J. (2012), "Vibration control using ATMD and site measurements on the Shanghai World Financial Center Tower", Struct. Des. Tall Spec., Doi: 10.1002/tal.1027.
  29. Marazzi, F. and Magonette, G. (2001), Active and semi-active control of structures: a comparison, European Meeting on Intelligent Structures, Ishia, Italy.
  30. Meirovitch, L. (1967), Analytical methods in vibrations, The Macmillan Co., New York.
  31. Metwally, H.M., El-Souhily, B.M. and Aly, A. (2006), "Reducing vibration effects on buildings due to earthquake using magneto-rheological dampers", Alex. Eng. J., 45(2), 131-140.
  32. Rosa, L., Tomasini, G., Zasso, A. and Aly, A.M. (2012), "Wind-induced dynamics and loads in a prismatic slender building: a modal approach based on unsteady pressure measurements", J. Wind Eng. Ind. Aerod., 107-108, 118-130 https://doi.org/10.1016/j.jweia.2012.03.034
  33. Satake, N., Suda, K., Arakawa, T., Sasaki, A. and Tamura, Y. (2003), "Damping evaluation using full-scale data of building in Japan", J. Struct. Eng. - ASCE, 129(4), 470-477. https://doi.org/10.1061/(ASCE)0733-9445(2003)129:4(470)
  34. Samali, B., Al-Dawod, M., Kwok K.C. and Naghdy, F. (2004), "Active control of cross wind response of 76-story tall building using a fuzzy controller", J. Eng. Mech.- ASCE, 130(4), 492-498. https://doi.org/10.1061/(ASCE)0733-9399(2004)130:4(492)
  35. Skelton, R. E. (1988). Dynamic systems control: Linear systems analysis and synthesis, Wiley, New York.
  36. Smith R.J. and Willford, M.R. (2007), "The damped outrigger concept for tall buildings", Struct. Des. Tall Spec., 16(4), 501-517. https://doi.org/10.1002/tal.413
  37. Sohn, H., Dzwonczyk, M., Straser, E.G., Kiremidjian, A.S., Law K.H. and Meng, T. (1999), "An 499 experimental study of temperature effect on modal parameters of the Alamosa Canyon Bridge", Earthq. Eng. Struct. D., 28(8), 879-97. https://doi.org/10.1002/(SICI)1096-9845(199908)28:8<879::AID-EQE845>3.0.CO;2-V
  38. Spencer, B.F., Jr., Dyke, S.J. and Deoskar, H.S. (1998), "Benchmark problems in structural control. I: Active mass driver system, and II: Active tendon system", Earthq. Eng. Struct. D., 27(11), 1127-1147. https://doi.org/10.1002/(SICI)1096-9845(1998110)27:11<1127::AID-EQE774>3.0.CO;2-F
  39. Tamura, Y. and Yoshida, A. (2008), "Amplitude dependency of damping in buildings", Proceedings of the 18th Analysis and Computation Specialty Conference, Vancouver, Canada.
  40. Taranath, B.S. (2005), Wind and earthquake resistant buildings: structural analysis and design, Marcel Dekker, New York.
  41. Warburton, G.B. and Ayorinde, E.O. (1980), "Optimum absorber parameters for simple systems", Earthq. Eng. Struct. D., 8(3), 197-217. https://doi.org/10.1002/eqe.4290080302
  42. Wu, J.C., Yang, J.N., Schmitendorf, W. (1998), "Reduced-order $H_{{\infty}}$ and LQR control for wind-excited tall buildings", Eng. Struct., 20(3), 222-236. https://doi.org/10.1016/S0141-0296(97)00081-3
  43. Xia, Y., Hao, H., Zanardo, G. and Deeks, A., (2006), "Long term vibration monitoring of an RC slab: temperature and humidity effect", Eng. Struct., 28(3), 441-52. https://doi.org/10.1016/j.engstruct.2005.09.001
  44. Yan, J., Ryan, M., and Power, J. (1994), Using Fuzzy Logic: Towards Intelligent Systems, Prentice Hall, New York.
  45. Yang, J.N., Agrawal, A.K., Samali, B. and Wu, J.C. (2004), "Benchmark problem for response control of wind-excited tall buildings", J. Eng. Mech.- ASCE, 130(4), 437-446. https://doi.org/10.1061/(ASCE)0733-9399(2004)130:4(437)
  46. Yuen, K.V. and Kuok, S.C. (2010a), "Ambient interference in long-term monitoring of buildings", Eng. Struct., 32(8), 2379-2386. https://doi.org/10.1016/j.engstruct.2010.04.012
  47. Yuen, K.V. and Kuok, S.C. (2010b), "Modeling of environmental influence in structural health assessment for reinforced concrete buildings", Earthq. Eng. Eng. Vib., 9(2), 295-306. https://doi.org/10.1007/s11803-010-0014-4
  48. Zasso, A., Aly, A.M., Rosa, L. and Tomasini, G. (2008), "Wind induced dynamics of a prismatic slender building with 1:3 rectangular section", Proceedings of the BBAA VI International Colloquium on Bluff Bodies Aerodynamics & Applications, Milano, Italy, 20-24 July.

Cited by

  1. Robustness of multi-mode control using tuned mass dampers for seismically excited structures vol.15, pp.12, 2017, https://doi.org/10.1007/s10518-017-0187-6
  2. Seismic control response of structures using an ATMD with fuzzy logic controller and PSO method vol.51, pp.4, 2014, https://doi.org/10.12989/sem.2014.51.4.547
  3. Research developments in vibration control of structures using passive tuned mass dampers vol.44, 2017, https://doi.org/10.1016/j.arcontrol.2017.09.015
  4. Performance of TMDs on nonlinear structures subjected to near-fault earthquakes vol.16, pp.4, 2015, https://doi.org/10.12989/sss.2015.16.4.725
  5. Vibration control in wind turbines for performance enhancement: A comparative study vol.22, pp.1, 2016, https://doi.org/10.12989/was.2016.22.1.107
  6. Closed-form optimum tuning formulas for passive Tuned Mass Dampers under benchmark excitations vol.17, pp.2, 2016, https://doi.org/10.12989/sss.2016.17.2.231
  7. Structural Improvements for Tall Buildings under Wind Loads: Comparative Study vol.2017, 2017, https://doi.org/10.1155/2017/2031248
  8. Seismic Energy Assessment of Buildings with Tuned Vibration Absorbers vol.2018, pp.1875-9203, 2018, https://doi.org/10.1155/2018/2051687
  9. Optimum Tuning of Passive Tuned Mass Dampers for the Mitigation of Pulse-Like Responses vol.140, pp.6, 2018, https://doi.org/10.1115/1.4040475
  10. LQG vibration control effectiveness of an electric active mass damper considering soil–structure interaction pp.2195-2698, 2018, https://doi.org/10.1007/s40435-018-0428-9
  11. Effect of SSI on Vibration Control of Structures with Tuned Vibration Absorbers vol.2019, pp.1875-9203, 2019, https://doi.org/10.1155/2019/7463031
  12. Self-control of high rise building L-shape in plan considering soil structure interaction vol.6, pp.3, 2014, https://doi.org/10.12989/csm.2017.6.3.229
  13. A system of multiple controllers for attenuating the dynamic response of multimode floor structures to human walking vol.23, pp.5, 2014, https://doi.org/10.12989/sss.2019.23.5.467
  14. Reduced-mass Adaptive TMD for Tall Buildings Damping vol.8, pp.2, 2014, https://doi.org/10.21022/ijhrb.2019.8.2.117
  15. Active Tuned Mass Dampers for Control of Seismic Structures vol.19, pp.None, 2014, https://doi.org/10.37394/23205.2020.19.17
  16. An integrated damping system for tall buildings vol.29, pp.7, 2014, https://doi.org/10.1002/tal.1724
  17. Performance of TMDI for Tall Building Damping vol.9, pp.4, 2020, https://doi.org/10.3390/act9040139
  18. Tuned Mass Damper Design for Slender Masonry Structures: A Framework for Linear and Nonlinear Analysis vol.11, pp.8, 2021, https://doi.org/10.3390/app11083425
  19. Evaluation of TMD Performance in Footbridges Using Human Walking Probabilistic Models vol.4, pp.2, 2021, https://doi.org/10.3390/vibration4020021