DOI QR코드

DOI QR Code

An Experimental Study on Smoke Movement by the External Wind in Road Tunnel Fires

도로터널 화재 시 외부 바람에 의한 연기거동 특성에 관한 실험적 연구

  • 이성룡 (중앙소방학교 소방과학연구실)
  • Received : 2014.08.07
  • Accepted : 2014.08.26
  • Published : 2014.08.31

Abstract

In this study, reduced scale experiments were carried out to evaluate the effect of external wind in a road tunnel fire. Experiments were conducted in a $1.1m{\times}0.5m{\times}50.4m$ tunnel. 4.5 litter gasoline was used as a fuel. Temperature, oxygen and carbon monoxide concentration were measured. Smoke reaching time to the tunnel exit was affected by the external wind. When a fire was fully developed, wind effect is reduced compared with the early stage of a fire. CO concentration was reached at more than 1,500 ppm.

본 연구에서는 도로터널 화재 시 외부 바람에 의한 영향을 평가하기 위하여 축소모형 실험을 실시하였다. $1.1m{\times}0.5m{\times}50.4m$ 모형 터널에서 휘발유 4.5리터를 사용하여 실험을 실시하였다. 터널 내부의 온도, 산소와 일산화탄소 농도를 측정하였다. 외부 바람의 영향에 따라 연기의 출구 도달 시간에 차이를 보였다. 최성기 이후에는 외부 바람의 영향이 초기에 비하여 작은 것을 확인할 수 있었다. 화재로 인하여 발생한 일산화탄소가 1,500 ppm 이상 도달하여 피난자에게 치명적인 위해를 가할 수 있다.

Keywords

References

  1. MOLIT-related statistics, The Ministry of Land, Infrastructure and Transport, http://stat.molit.go.kr/.
  2. Yoo, Y.N., Park, S.H., Han, S.J., and Shin, H.J., 2004, A Evaluation Study of Local Smoke Control Facility for the Smoke Spread Prevention on Tunnel Fire, Journal of the Korean Society of Hazard Mitigation, 14-1, 43-48.
  3. Yoo, J.O., Oh, B.C. and Kim, H.G., 2013, A Numerical Study on the Characteristics of the Smoke Movement and the Effects of Structure in Road Tunnel Fire, Journal of Korean Tunnelling and Underground Space Association, 15-3, 289-300. https://doi.org/10.9711/KTAJ.2013.15.3.289
  4. Kim, D.Y. and Lee, C.W., 2010, A Study on Jet Fan Start Time in Medium-Length Tunnel Fires, Tunnel and Underground Space, 20-6, 465-474.
  5. Park, K.H. and So, S.H., 2010, A Real Scale Test on Performance of Water Spray Systems in Tunnel Fire, Tunnelling Technology, 12-4, 341-347.
  6. Quintiere, J.G., 1989, Scaling Applications in Fire Research, Fire Safety Journal, 15, 3-29. https://doi.org/10.1016/0379-7112(89)90045-3
  7. Hottel, H.C., 1961, Fire Modeling. The Use of Models in Fire Research, Publication 786 National Academy of Sciences, Washington DC, 32-47.
  8. Heskestad, G., 1975, Similarity Relations for the Initial Convective Flow Generated by Fire, Paper 72-WA/HT-17, American Society of Mechanical Engineers.
  9. Heskestad, G., 1975, Physical Modeling of Fire, Journal of Fire and Flammability, 6, 253- 272.
  10. Megret. O., Vauquelin, O., 2000, A model to evaluate tunnel fire characteristics, Fire Safety Journal 34, 393-401. https://doi.org/10.1016/S0379-7112(00)00010-2
  11. Edward, K.B., Harold, E.N. and David, D.E., 1997, Simplified Fire Growth Calculation, Fire Protection Handbook, 18th Edition, NFPA FPH1897, Section 11, Chapter 10.
  12. Fire and Smoke Control in Road Tunnels, 1999, PIARC.