DOI QR코드

DOI QR Code

Fouling Characteristics of Washable Shell and Coil Heat Exchanger

세척이 가능한 원통 코일형 열교환기의 파울링 특성에 관한 연구

  • Received : 2014.09.11
  • Accepted : 2014.11.07
  • Published : 2015.02.10

Abstract

In this work, we studied the shell and helically coiled tube heat exchangers. Shell and coil heat exchangers with different rate of water flow and plate heat exchanger with same capacity were tested for condensing conditions. We proposed design guide using modified Wilson plot method. We compared fouling characteristics between shell and coil heat exchanger and plate heat exchanger, when they were washed and were not washed. The shell and coil heat exchanger showed 120% of higher saturated fouling resistance value and 4% of better heat transfer ratio than the plate heat exchanger.

Keywords

References

  1. Sung, S. K., Suh, S. H., and Roh, H. W., 2004, Analysis of fouling mechanism using visualization techniques in a lab-scale plate type heat exchanging system, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16, No. 4, pp. 349-354.
  2. Sung, S. K., Suh, S. H., and Roh, H. W., 2005, Cooling water fouling characteristics and physical water treatment in heat exchanging system, Proceedings of the KSME 2005 Spring Symposium, Vol. 5, pp. 2596-2601.
  3. Thonon, B., Grandgeorge, S., and Jallut, C., 1999, Effect of geometry and flow conditions on particulate fouling in plate heat exchangers, Heat Transfer Engineering, Vol. 20, No. 3, pp. 13-25.
  4. Inoue, N., Iku, S., and Watanabe, K., 2012, Pressure drop and heat transfer inside the coiled flow channel of smooth tubes and internally helical-grooved tubes, International Journal of Air-Conditioning and Refrigeration, Vol. 20, No. 4, pp. 1250023.1-1250023.14. https://doi.org/10.1142/S201013251250023X
  5. Seara, J. F., Uhla, F. J., Sieres, J., and Campo, A., 2007, A general review of the Wilson plot method and its modifications to determine convection coefficients in heat exchange devices, Applied Thermal Engineering, Vol. 27, No. 17/18, pp. 2745-2757. https://doi.org/10.1016/j.applthermaleng.2007.04.004
  6. Bansal, B., Steinhagen, H. M. and Chen, X. D., 2001, Comparison of crystallization fouling in plate and double-pipe heat exchangers, Heat Transfer Engineering, Vol. 22, No. 1, pp. 13-25. https://doi.org/10.1080/01457630117263

Cited by

  1. Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 vol.28, pp.6, 2016, https://doi.org/10.6110/KJACR.2016.28.6.256