DOI QR코드

DOI QR Code

Experimental Study on Separate Evaluations of Fire Resistance of SFRM for Steel Beams and Columns

내화뿜칠재 보와 기둥의 내화성능 분리평가에 대한 실험적 연구

  • Jeon, Soo-Min (Dept. of Architectural Engineering, HanYang Univ.) ;
  • Kim, Jae-Jun (Dept. of Architectural Engineering, HanYang Univ.)
  • Received : 2015.04.01
  • Accepted : 2015.06.23
  • Published : 2015.08.31

Abstract

It is necessary to obtain a fire resistance certification in order to use SFRM in Korea. The fire resistance tests for certifications are performed separately for beams and columns and the certifications are different. We could assume that the same SFRM has different thicknesses for beams and columns because the conditions of the fire resistance tests for them differ in the section factors etc. But most of the SFRMs in Korea have the same thicknesses for beams and columns. So the question arises as to there were the differences between the fire test results for beams and columns reside. The purpose of this study is to consider the separate evaluation of the fire resistance of members through a comparative analysis of the temperature data obtained from fire certification tests.

강구조용 내화뿜칠재는 내화구조로 인정을 받아야 사용할 수 있는데 내화뿜칠재 인정시 보와 기둥이 분리되어 평가 및 인정되고 있다. 보와 기둥의 내화시험 표준시험체는 단면형상계수 등이 상이하므로 내화피복 두께산정방법(KS F 2848)에 따르면 동일피복재를 사용하는 경우 동일성능의 보용 뿜칠재와 기둥용 뿜칠재는 피복두께가 상이할 것으로 예상할 수 있다. 그러나 현재 인정이 유효한 내화뿜칠재의 보 기둥 피복두께는 제품별로 서로 동일하거나 매우 유사하다. 그렇다면 동 뿜칠재의 내화구조 인정을 위한 성능시험시 보와 기둥의 강재평균온도에 차이가 있었을 것이라고 추정해 볼 수 있다. 본 연구를 통하여 보용 또는 기둥용 내화뿜칠재의 강재평균온도를 비교분석하여, 보용 기둥용으로 분리하여 평가 및 인정하고 있는 현 제도를 검토해 보고자 한다.

Keywords

References

  1. I. K. Kwon, N. Y. Jee and H. Y. Kim, "Experimental Study on the Determination of Fire Protection Thickness through Section Factors of Structural Steels", Journal of the Architectural Institute of Korea, Vol. 18, No. 9, pp. 125-132 (2002).
  2. C. W. Jung, N. Y. Jee and I. K. Kwon, "Study on the Determination of Fire Protection Thickness based on Section Factor", Proceedings of 2003 Spring Annual Conference, Korean Institute of Building Construction, pp. 139-142 (2003).
  3. S. H. Lee, K. H. Kim, M. S. Lee, H. Y. Kim, H. D. Kim, T. H. Song, C. Y. Ok, B. K. Jin, et al., "Development of Fire Resistance Design Method in Building", KICT 2004-376, Korea Institute of Civil Engineering and Building Technology (2004).
  4. T. S. Shin, "An Analysis and Evaluation of Fire Resistance Performance for the Protected Steel Columns in Korea", Journal of Korean Society of Steel Construction, Vol. 21, No. 1, pp. 27-35 (2009).
  5. S. C. Kim, "Correlation Analysis with Fire Endurance Time based on Section Factor to Obtain an Estimate of Fire Protection Material Thickness", Architectural Engineering Master's Thesis, Chungju National University (2009).
  6. H. S. Kim and J. Kang, "A Study on the Determination of Required Fire Protection Thickness Considering Steel Section Shape", Journal of the Korea Academia-Industrial Cooperation Society, Vol. 12, No. 12, pp. 5910-5916 (2011). https://doi.org/10.5762/KAIS.2011.12.12.5910
  7. Korea Agency for Technology and Standards, "Method for Calculating Fire Protective Thickness of Structural Steel According to Section Factor", KS F 2848:2010 (2010).
  8. Korea Agency for Technology and Standards, "Methods of fire Resistance Test for Elements of Building Construction-General Requirements", KS F 2257-1:2014 (2014).
  9. Korea Agency for Technology and Standards, "Methods of Fire Resistance Test for Elements of Building Construction-Specific Requirements for Beams", KS F 2257- 6:2014 (2014).
  10. Korea Agency for Technology and Standards, "Methods of Fire Resistance Test for Elements of Building Construction-Specific Requirements for Columns", KS F 2257-7:2014 (2014).
  11. Korea Agency for Technology and Standards, "Dimensions, Mass and Permissible Variations of Hot Rolled Steel Sections", KS D 3502:2013 (2012).
  12. Ministry of Land, Infrastructure and Transport, "The Evacuative and Fireproof Construction of Buildings", Minister Decree No:149 (2014).
  13. Ministry of Land, Infrastructure and Transport, "Standards for Accreditation and Management of Fire Resistant Construction", Notification No:2014-200 (2014).
  14. Ministry of Land, Infrastructure and Transport, "Detail Instructions for Accreditation and Management of Fire Resistant Construction", Document No:7749 (2012).
  15. Korea Institute of Civil Engineering and Building Technology, "Certificate List of Fire Resistant Construction", http://cert.kict.re.kr/ (2015).