Abstract

Modular building is a prefabricated construction system for building where factory-produced pre-engineered modular units are delivered to site and assembled as substantial elements of a building. There are two basic kinds of modular structures. One is a load-bearing wall structure designed to transfer the load through longitudinal walls. The other is a frame structure composed of columns and beams. For frame structure, square hollow section is often used as a column member and channel as a beam member in modular unit. Lower and upper modules are fasten with bolts via a pre-installed access hole in the SHS column. However, the access holes can weaken the panel zone that would affect the behavior of beam to column connection. The 5 specimens of beam to column connections with parameters of access hole, column thickness and diaphragm were made and this paper describes the test results.

모듈러 건축은 사전에 설계 검토된 건물 요소를 공장에서 모듈로 제작하여 현장으로 운송 조립하는 프리패브 건축 시스템이다. 모듈러 건축물의 구조 형식은 공법, 재료, 부재 구성 등에 따라 다양하게 구분될 수 있지만 사용되는 모듈의 구조 형식은 크게 벽식과 가구식으로 나눌 수 있다. 벽식 모듈은 모듈의 입면을 패널을 이용하여 구성하여 수직하중과 수평하중을 전달시키는 방식이다. 가구식 모듈은 기둥과 보를 이용하여 모듈을 구성하고, 용도에 맞춰 입면을 마감하거나 개방시켜 놓는 방식이다. 이 두 가지 모듈 방식은 국내에도 사용된 바 있으나 최근 가구식 모듈이 보편화되고 있다. 가구식 모듈의 기둥 부재로 각형강관이 일반적으로 사용되고 있으며, 보 부재로 C형강 또는 H형강이 사용되고 있다. 각형강관이 기둥 부재로 사용된 가구식 모듈간 접합을 위해 각형강관 기둥 단부에 고력볼트를 채우기 위해 액세스 홀을 가공하는 경우가 있다. 액세스 홀은 볼트체결을 위해 사람의 손이나 공구가 폐쇄형 단면인 각형강관 내부에 접근하기 위한 개구부로 액세스 홀은 기둥-보 접합부의 거동에 영향을 미치는 패널존을 약화시킬 가능성이 높다. 이 연구에서는 가구식 모듈의 기둥-보 접합부 거동에 영향을 미치는 액세스 홀, 기둥 두께, 다이아프램을 변수로 5개의 실험체를 제작하여 실험을 실시하였고 그 결과를 분석하여 제시하였다.

Keywords

References

  1. 조봉호, 김홍진, 고광호(2007) 모듈러 건축 시스템의 기술 개발 동향 및 적용 사례, 한국강구조학회지, 한국강구조학회, 제19권, 제1호, pp.112-119. Cho, B.H., Kim, H.J., and Ko, G.H. (2007) The State of Art in the Modular Construction in Korea, Magazine of Korean Society of Steel Construction, KSSC, Vol.19, No.1, pp.112-119 (in Korean).
  2. Lawson, R.M., Byfield, M.P., Popo-Ola, S.O., and Grubb, P.J. (2008). Robustness of Light Steel Frames and Modular Construction, Proceedings of the ICE - Structures and Buildings, Institution of Civil Engineers, Vol.161, Issue1, pp.3-16.
  3. Issa J. Ramaji, and Ali M. Memari (2013) Identification of Structural Issues in Design and Construction of Multi- Story Modular Buildings, 1st Residential Building Design & Construction Conference, PHRC, pp.294-303.
  4. 심성철, 이상현, 조봉호, 우성식, 최문식(2008) $12m{\times}3m$ 스틸 모듈러 시스템의 보-중간기둥 접합부 구조성능, 한국강구조학회논문집, 한국강구조학회, 제20권, 제6호, pp. 793-805. Shim, S.C., Lee, S.H., Jo, B.H., Woo, S.S., and Choi, M.S. (2008) Structural Performance of Beam-Middle Column Connection of $12m{\times}3m$ Steel Modular System, Journal of Korean Society of Steel Construction, KSSC, Vol.20, No.6, pp.793-805 (in Korean).
  5. 정성림, 강주원, 박성무(2008) 해체 조립식 모듈러 철골조 기둥-보 접합부의 거동에 관한 실험적 연구, 한국공간구조학회지, 한국공간구조학회, 제8권, 제1호, pp.89-97. Zheng, S.L., Kang, J.W., and Park, S.M. (2008) An Experimental Study on the Behavior of Beam-to-Column Joints for Modular Steel Frame, Journal of the Korean association for shell and spatial structures, KASSS, Vol.8, No.1, pp.89-97 (in Korean).
  6. 박금성, 이상섭, 임석호, 배규웅(2009) 접합부 형상변화에 따른 경ㄷ-형강 보의 거동에 관한 연구, 대한건축학회논문집 구조계, 대한건축학회, 제25권, 제1호, pp.89-96. Park, K.S., Lee, S.S., Lim, S.H., and Bea, K.W. (2009) The Behavior on the Beam of Light Steel Section with Shapes changed of Connections, Journal of the Architectural Institute of Korea, AIK, Vol.25, No.1, pp.89-96 (in Korean).
  7. 이상섭, 배규웅, 박금성, 홍성엽(2013) 유닛 모듈러 기둥- 보 조인트의 구조 성능에 대한 실험적 평가, 한국강구조학회논문집, 한국강구조학회, 제25권, 제3호, pp.255-265. Lee, S.S., Bea, K.W., Park, K.S., and Hong, S.Y. (2013) An Experimental Evaluation of Structural Performance for the Beam to Column Joints in Unit Modular System, Journal of Korean Society of Steel Construction, KSSC, Vol.25, No.3, pp.255-265 (in Korean).
  8. 한국산업표준(2003) KS B 0802 금속재료 인장 시험 방법, 한국표준협회. Korean Standards (2003) KS B 0801 Method of Tensile Test for Metallic Materials, Korean Standards Association (in Korean).
  9. 대한건축학회(2011) 건축구조설계기준 및 해설(KBC 2009) 기문당. The Architectural Institute of Korea (2009) Korean Building Code and Commentary (KBC 2009), Kimoondang (in Korean).
  10. AISC (2010) Seismic Provisions for Structural Steel Buildings, American Institute of Steel Construction, USA.
  11. CEN (2005) Eurocode 3: Design of steel structures, part 1.8 : Design of joints (EN 1993-1-8:2005), London : British Standards Institution.

Cited by

  1. Influence of Analytical Models on the Seismic Response of Modular Structures vol.20, pp.2, 2016, https://doi.org/10.11112/jksmi.2016.20.2.074
  2. 스트랩 브레이스를 갖는 내력벽식 모듈러건축 스틸스터드 벽체의 반복하중에 대한 거동 연구 vol.28, pp.6, 2016, https://doi.org/10.7781/kjoss.2016.28.6.415
  3. 합성단면을 적용한 모듈러 시스템의 내진 성능평가 vol.21, pp.2, 2015, https://doi.org/10.11112/jksmi.2017.21.2.069
  4. 강-PC 복합모듈러 골조의 합성보에 대한 구조성능 평가 vol.29, pp.5, 2015, https://doi.org/10.7781/kjoss.2017.29.5.331
  5. 접합부 강성을 고려한 합성 모듈러 시스템의 내진 성능평가 vol.22, pp.2, 2015, https://doi.org/10.11112/jksmi.2018.22.2.105
  6. Seismic Performance Evaluation of H-Shape Beam-to-Column Connection in Modular System vol.31, pp.4, 2019, https://doi.org/10.7781/kjoss.2019.31.5.339
  7. Structural Performance Evaluation of Modular Connection Using Specially Fabricated Blocks vol.32, pp.4, 2020, https://doi.org/10.7781/kjoss.2020.32.4.257
  8. Study on Mechanical Performance of Connection jointsIn Novel Modular Steel Structure Buildings vol.605, pp.None, 2020, https://doi.org/10.1088/1755-1315/605/1/012015