DOI QR코드

DOI QR Code

A Simulation Method for Considering the Outdoor Wind-Pressure in Calculation of Indoor Air-Flow in High-Rise Buildings

건물 내 공기유동 해석에 외부 바람이 미치는 영향의 분석

  • Kim, Dae-Young (Department of Global Construction Engineering, Sungkyunkwan University) ;
  • Song, Doo-Sam (School of Architectural, Civil and Environmental Engineering, Sungkyunkwan University)
  • 김대영 (성균관대학교 글로벌건설엔지니어링학과) ;
  • 송두삼 (성균관대학교 건축토목공학부)
  • Received : 2015.11.23
  • Accepted : 2015.12.30
  • Published : 2016.02.10

Abstract

The air flows in building caused by thermal buoyancy, known as the stack effect, have a pronounced influence on both the indoor environment (thermal environment, noise, draught and contaminant diffusion) and energy needs in high-rise buildings. Prior studies for airflow in high-rise buildings were focused on the degree of stack effect and countermeasures. The wind pressure was neglected during the calculation of the indoor airflow in high-rise buildings to clarify the effect of thermal buoyancy in previous studies. However, wind is an important driving force of indoor airflows in buildings with the stack effect. In this study, the effect of wind pressure on indoor airflow in high-rise building when the stack effect is dominant in winter was analyzed. In this paper, methods that involved considering the wind pressure in airflow network simulation were analyzed.

Keywords

References

  1. Song, D. S., 2012, A Study on the Formation of Indoor Contaminant Concentration by Vertical Airflow in High-Rise Residential Buildings, The Society Of Air-Conditioning And Refrigerating Engineers Of Korea, Vol. 2012, No. 11, pp. 129-136.
  2. Jo, J. H., 2010, Evaluation of Problems and Field Measurement of Stack Pressure Profiles in the highrise Office Building, Architectural Institute of Korea, Vol. 26, No. 7, pp. 330-340.
  3. Swami, M. V. and Chandra, S., 1988, Correlations for pressure distributions on buildings and calculation of natural-ventilation airflow, ASHRAE Transactions, Vol. 94, No. 1, pp. 243-266.
  4. Persily, A. K. and Ivy, E. M., 2001, Input data for multizone airflow and IAQ analysis, Gaithersburg, MD., National Institute of Standard and Technology.
  5. Gao, Y., 2002, Coupling of computational fluid dynamics and a multizone airflow analysis program for indoor environmental design, Cambridge, MA., Massachusetts Institute of Technology.
  6. Jiang, Y., Alexander, D., Jenkins, H., Arthur, R., and Chen, Q., 2003, Natural ventilation in buildings:measurement in a wind tunnel and numerical simulation with large eddy simulation, Journal of Wind Engineering and Industrial Aerodynamics, Vol. 91, No. 3, pp. 331-353. https://doi.org/10.1016/S0167-6105(02)00380-X
  7. Wang, L., 2007, Coupling of multizone and CFD programs for building airflow and contaminant transport simulations. Mechanical Engineering, West Lafayette, IN, Purdue University. Ph.D Thesis.
  8. Feustel, H. E., 2005, COMIS 3.2-user guide, Dubendorf: Empa.
  9. Eldin, A. S., 2007, A parametric model for predicting wind-induced pressures on low rise vertical surfaces in shielded environments, Solar Energy, Vol. 81, No. 1, pp. 52-61. https://doi.org/10.1016/j.solener.2006.06.007
  10. ASHERAE, 2005, ASHERAE Handbook-Fundamentals (SI), American Society of Heating, Refrigeration, and Air-conditioning Engineers, Inc., Chapter 16.
  11. Hu, C. H. and Wang, F., 2005, Using a CFD approach for the study of street-level winds in a built area, Building and Environment Vol. 40, No. 5, pp. 617-631. https://doi.org/10.1016/j.buildenv.2004.08.016