DOI QR코드

DOI QR Code

Flow Characteristics of Ejector Driven Pipe According to the Changes of Diameter Ratio and End Position

이젝터 구동관로의 직경비와 끝단의 위치 변화에 따른 유동특성

  • Received : 2015.06.19
  • Accepted : 2016.01.13
  • Published : 2016.02.01

Abstract

This study conducted CFD analysis on the mean velocity vector of distribution of the ejector driven pipe while changing the inlet velocity to 1 m/s at the diameter ratio of diffuser of 1:3, 1:2.25, 1:1.8 with the end position of driven pipe at 1, 1.253, 1.333, 1.467 respectively, which used $k-{\varepsilon}$/High Reynolds Number for the turbulence model, SIMPLE method for the analysis algorithm, and PIV experiment to verify the CFD analysis. As a result of the CFD analysis the optimum diameter ratio of ejector driven pipe was 1:3, the optimum end position of driven pipe was 1.333 for the diameter ratio of 1:3, 1:2.25, 1:1.8 and the PIV experiment obtained the same result as the CFD analysis. Therefore, the numerical analysis of the flow characteristics of ejector can be used for the optimum design implementation on ejector system.

Keywords

References

  1. Fluegel Gustav, 1939, "Berechung von Strahlapparaten," VDI-Forschungsheft 395 Ausgabe B Band 10 March/April.
  2. Sun, D. W. and Eames, I. E., 1995, "Recent Developments in the Design Theories and Applications of Ejectors a Review," Journal of the Institute Energy, Vol. 68, Jun., pp. 665-676.
  3. Witte, J. H., 1995, "Efficiency and Design of Liquid-Gas Ejector," British-Chemical Engineering, Vol. 10, No. 9, pp. 602-607.
  4. U., J., Kim, 2008, "A Study on the Effect of Nozzle Geometry on the Suction Flow Rate in a Jet Pump," The Graduate School of Dong-A University, Master's thesis.
  5. J., H., Jeong, 2011, "A Study of Flow Characteristics Inside of Ejector," The Graduate School of Dong-A University, Master's thesis.

Cited by