DOI QR코드

DOI QR Code

Precise Determination of Silicon in Ceramic Reference Materials by Prompt Gamma Activation Analysis at JRR-3

  • Received : 2016.02.10
  • Accepted : 2016.02.18
  • Published : 2016.04.25

Abstract

Prompt gamma activation analysis using a thermal neutron-guided beam at Japan Atomic Energy Agency JRR-3M was applied for the precise determination of Si in silicon nitride ceramic reference materials [Japan Ceramic Reference Material (JCRM) R 003]. In this study, the standard addition method coupled with internal standard was used for the nondestructive determination of Si in the sample. Cadmium was used as internal standard to obtain the linear calibration curves and to compensate for the neutron beam variability. The analytical result of determining Si in JCRM R 003 silicon nitride fine powder ceramic reference materials using prompt gamma activation analysis was in good agreement with that obtained by classical gravimetric analysis. The relative expanded measurement uncertainty (k = 2) associated with the determined value was 2.4%.

Keywords

References

  1. R.R. Greenberg, P. Bode, E.A.D. Fernandes, Neutron activation analysis: a primary method of measurement, Spectrochim. Acta B 66 (2011) 193-207. https://doi.org/10.1016/j.sab.2010.12.011
  2. R.L. Paul, R.M. Lindstrom, Preparation and certification of hydrogen in titanium alloy standard reference materials, Metall. Mater. Trans. A 43A (2012) 4888-4895.
  3. C. Yonezawa, A.K.H. Wood, Prompt gamma-ray analysis of boron with cold and thermal neutron guided beams, Anal. Chem. 67 (1995) 4466. https://doi.org/10.1021/ac00120a006
  4. Sk. Latif, Y. Ourac, M. Ebihara, G.W. Kallenmeyn, H. Nakahara, C. Yonezawa, H. Matsue, H. Sawahata, Prompt gamma-ray analysis (PGA) of meteorite samples, J. Radioanal. Nucl. Chem. 239 (1999) 577. https://doi.org/10.1007/BF02349072
  5. C. Yonezawa, H. Matsue, Usefulness of prompt gamma-ray analysis with guided beams compared to NAA, J. Radioanal. Nucl. Chem. 244 (2000) 373-378. https://doi.org/10.1023/A:1006739710086
  6. S. Yamada, T. Shiniohara, H. Sasao, T. Oku, J. Suzuki, H. Matsue, H. Shimizu, Development of a multichannel parabolic guided for thermal neutron beam focusing, Physica B 385-386 (2006) 1243. https://doi.org/10.1016/j.physb.2006.05.420
  7. T. Miura, H. Matsue, T. Kuroiwa, K. Chiba, Determination of boron in ceramics reference materials by prompt gamma activation analysis using focused neutron guided beam of JRR-3M, J. Radioanal. Nucl. Chem. 278 (2008) 653-656. https://doi.org/10.1007/s10967-008-1403-2
  8. Certificate of JCRM R 003 silicon nitride powder, The Ceramics Society of Japan, 2003.
  9. Database for Prompt Gamma-ray Neutron Activation Analysis. [cited 2016 Feb 10] Available from: www-nds.iaea.org/pgaa/.
  10. C. Yonezawa, A.K.H. Wood, M. Hoshi, Y. Ito, E. Tachikawa, The characteristics of the prompt gamma-ray analyzing system at the neutron beam guides of JRR-3M, Nucl. Instrum. Methods Phys. Res. A 329 (1993) 207-216. https://doi.org/10.1016/0168-9002(93)90938-E
  11. H. Matsue, C. Yonezawa, $k_0$ Standardization approach in neutron-induced prompt gamma-ray analysis at JAERI, J. Radioanal. Nucl. Chem. 245 (2000) 189-194. https://doi.org/10.1023/A:1006799213794
  12. S. Raman, C. Yonezawa, H. Matsue, H. Iimura, N. Shinohara, Efficiency calibration of a Ge detector in the 0.1-11.0 MeV region, Nucl. Instrum. Methods A 454 (2000) 389. https://doi.org/10.1016/S0168-9002(00)00493-9
  13. C. Yonezawa, Multi-elemental determination by a cold neutron-induced prompt gamma-ray analysis, Anal. Sci. 12 (1996) 605-613. https://doi.org/10.2116/analsci.12.605
  14. J.N. Miller, J.C. Miller, Statistics and Chemometrics for Analytical Chemistry, 6th ed., Pearson, England, 2010.

Cited by

  1. Neutron activation analysis: Modelling studies to improve the neutron flux of Americium-Beryllium source vol.49, pp.4, 2016, https://doi.org/10.1016/j.net.2017.02.002