Assessment of the fit of zirconia-based prostheses fabricated with two different scan methods

서로 다른 두 가지 스캔법을 이용하여 제작된 지르코니아 보철물의 적합도에 대한 비교

  • Choi, Hyun-Suk (Department of Prosthodontics, School of Dentistry, Kyoungpook National University) ;
  • Cho, Jin-Hyun (Department of Prosthodontics, School of Dentistry, Kyoungpook National University)
  • 최현석 (경북대학교 치과대학 치과보철학교실) ;
  • 조진현 (경북대학교 치과대학 치과보철학교실)
  • Received : 2016.10.05
  • Accepted : 2016.11.23
  • Published : 2017.04.28

Abstract

Purpose: This research was conducted to compare the marginal and internal fit of zirconia prostheses fabricated with the model scan method and the intraoral scan method. Materials and methods: In this study, 20 extracted human mandibular first molar was used in the preparation of abutment tooth for the fabrication of zirconia prostheses. In the first group, the model scan method was applied on 10 prepared teeth. In the other group, the intraoral scan method was used on other 10 prepared teeth. Datum of both groups were transmitted to the software system. Afterwards, 20 zirconia prostheses were fabricated using the Ceramill system. Weight technique was used to evaluate the internal gap of the zirconia prostheses. In the Replica technique, marginal gap of the zirconia prostheses were analyzed by optical microscopy. Statistical analysis was based on one-way ANOVA. Results: Model scan group showed lower average weight than intraoral scan group when weight technique was applied, which has significance (P < .05). Also, model scan group showed significantly lower figures in all 5 measurements of replica technique than intraoral scan group (P < .05). Conclusion: Zirconia prostheses of both groups demonstrated clinically acceptable margin and internal fit. However, model scanned zirconia prostheses showed higher marginal and internal fit than intraoral scanned crowns.

목적: 연구의 목적은 동일한 지대치에서 각각 모델스캔 방법과 구강 내 스캔 방법으로 제작된 지르코니아 보철물의 변연 및 내면적합도를 비교하는 것이다. 재료 및 방법: 발거된 사람의 하악 제1대구치 20개에 대해 지르코니아 보철물을 위한 지대치 형성이 이루어졌다. 첫 번째 그룹에서는 모델 스캔법으로 10개의 지대치를 스캔하였고, 두 번째 그룹에서는 나머지 10개에 대해 구강 내 스캔법을 사용하였다. 각각의 데이터들은 소프트웨어 시스템으로 전송되었고 Ceramill CAD/CAM system을 이용하여 20개의 지르코니아 보철물을 제작하였다. 먼저 weight technique을 사용하여 내면 적합도를 평가하였다. 다음으로 replica technique에서는 광학현미경을 통해 변연 적합도를 평가하였다. 통계처리는 일원배치분산분석을 이용하였다. 결과: 먼저 weight technique에서 모델 스캔법으로 제작한 그룹에서 구강 내 스캔법으로 제작한 그룹에 비해 평균적인 무게 값이 낮게 나타났고, 이는 유의성이 있었다(P < .05). 또한, replica technique에서도 측정된 5개의 영역 모두에서 구강 내 스캔법으로 제작한 그룹에 비해 모델 스캔법으로 제작한 그룹에서 변연 및 내면의 gap에 대한 거리 값이 유의하게 낮게 나타났다(P < .05). 결론: 두 그룹의 방법으로 제작한 지르코니아 보철물은 모두 임상적으로 받아들여질 만한 변연 및 내면 적합성을 보였다. 하지만 모델 스캔법으로 제작한 그룹에서 구강 내 스캔법으로 제작한 그룹에 비해 높은 변연 및 내면 적합성을 보였다.

Keywords

References

  1. Conrad HJ, Seong WJ, Pesun IJ. Current ceramic materials and systems with clinical recommendations: a systematic review. J Prosthet Dent 2007;98:389-404. https://doi.org/10.1016/S0022-3913(07)60124-3
  2. Martl'nez-Rus F, Sua'rez MJ, Rivera B, Pradl'es G. Evaluation of the absolute marginal discrepancy of zirconia-based ceramic copings. J Prosthet Dent 2011;105:108-14. https://doi.org/10.1016/S0022-3913(11)60009-7
  3. Patzelt SB, Lamprinos C, Stampf S, Att W. The time efficiency of intraoral scanners: an in vitro comparative study. J Am Dent Assoc 2014;145:542-51. https://doi.org/10.14219/jada.2014.23
  4. Cho YB, Chung CH, Kim HJ. Marginal and internal fit of copings made by CAD/CAM using different scanning methods. J Dent Rehab App Sci 2013;29:366-76. https://doi.org/10.14368/jdras.2013.29.4.366
  5. Jacobs MS, Windeler AS. An investigation of dental luting cement solubility as a function of the marginal gap. J Prosthet Dent 1991;65:436-42. https://doi.org/10.1016/0022-3913(91)90239-S
  6. Felton DA, Kanoy BE, Bayne SC, Wirthman GP. Effect of in vivo crown margin discrepancies on periodontal health. J Prosthet Dent 1991;65:357-64. https://doi.org/10.1016/0022-3913(91)90225-L
  7. Holden JE, Goldstein GR, Hittelman EL, Clark EA. Comparison of the marginal fit of pressable ceramic to metal ceramic restorations. J Prosthodont 2009;18:645-8. https://doi.org/10.1111/j.1532-849X.2009.00497.x
  8. Quintas AF, Oliveira F, Bottino MA. Vertical marginal discrepancy of ceramic copings with different ceramic materials, finish lines, and luting agents: an in vitro evaluation. J Prosthet Dent 2004;92:250-7. https://doi.org/10.1016/j.prosdent.2004.06.023
  9. Tan PL, Gratton DG, Diaz-Arnold AM, Holmes DC. An in vitro comparison of vertical marginal gaps of CAD/CAM titanium and conventional cast restorations. J Prosthodont 2008;17:378-83. https://doi.org/10.1111/j.1532-849X.2008.00302.x
  10. Pera P, Gilodi S, Bassi F, Carossa S. In vitro marginal adaptation of alumina porcelain ceramic crowns. J Prosthet Dent 1994;72:585-90. https://doi.org/10.1016/0022-3913(94)90289-5
  11. Kohorst P, Brinkmann H, Dittmer MP, Borchers L, Stiesch M. Influence of the veneering process on the marginal fit of zirconia fixed dental prostheses. J Oral Rehabil 2010;37:283-91. https://doi.org/10.1111/j.1365-2842.2009.02053.x
  12. Stappert CF, Dai M, Chitmongkolsuk S, Gerds T, Strub JR. Marginal adaptation of three-unit fixed partial dentures constructed from pressed ceramic systems. Br Dent J 2004;196:766-70. https://doi.org/10.1038/sj.bdj.4811390
  13. Wolfart S, Wegner SM, Al-Halabi A, Kern M. Clinical evaluation of marginal fit of a new experimental all-ceramic system before and after cementation. Int J Prosthodont 2003;16:587-92.
  14. Balkaya MC, Cinar A, Pamuk S. Influence of firing cycles on the margin distortion of 3 all-ceramic crown systems. J Prosthet Dent 2005;93:346-55. https://doi.org/10.1016/j.prosdent.2005.02.003
  15. Fonseca JC, Henriques GE, Sobrinho LC, de Go'es MF. Stressrelieving and porcelain firing cycle influence on marginal fit of commercially pure titanium and titanium-aluminum-vanadium copings. Dent Mater 2003;19:686-91. https://doi.org/10.1016/S0109-5641(03)00014-9
  16. Wettstein F, Sailer I, Roos M, Hammerle CH. Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures. Eur J Oral Sci 2008;116:272-9. https://doi.org/10.1111/j.1600-0722.2008.00527.x
  17. Gonzalo E, Sua'rez MJ, Serrano B, Lozano JF. A comparison of the marginal vertical discrepancies of zirconium and metal ceramic posterior fixed dental prostheses before and after cementation. J Prosthet Dent 2009;102:378-84. https://doi.org/10.1016/S0022-3913(09)60198-0
  18. Valderrama S, Van Roekel N, Andersson M, Goodacre CJ, Munoz CA. A comparison of the marginal and internal adaptation of titanium and gold-platinum-palladium metal ceramic crowns. Int J Prosthodont 1995;8:29-37.
  19. Baig MR, Tan KB, Nicholls JI. Evaluation of the marginal fit of a zirconia ceramic computer-aided machined (CAM) crown system. J Prosthet Dent 2010;104:216-27. https://doi.org/10.1016/S0022-3913(10)60128-X
  20. Han HS, Yang HS, Lim HP, Park YJ. Marginal accuracy and internal fit of machine-milled and cast titanium crowns. J Prosthet Dent 2011;106:191-7. https://doi.org/10.1016/S0022-3913(11)60120-0
  21. Reich S, Wichmann M, Nkenke E, Proeschel P. Clinical fit of allceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems. Eur J Oral Sci 2005;113:174-9. https://doi.org/10.1111/j.1600-0722.2004.00197.x
  22. Jesu's Sua'rez M, Lozano JF, Paz Salido M, Martl'nez F. Marginal fit of titanium metal-ceramic crowns. Int J Prosthodont 2005;18:390-1.
  23. Castillo de Oyague R, Sa'nchez-Jorge MI, Sa'nchez Turrio'n A, Monticelli F, Toledano M, Osorio R. Influence of CAM vs. CAD/CAM scanning methods and finish line of tooth preparation in the vertical misfit of zirconia bridge structures. Am J Dent 2009;22:79-83.
  24. Holmes JR, Bayne SC, Holland GA, Sulik WD. Considerations in measurement of marginal fit. J Prosthet Dent 1989;62:405-8. https://doi.org/10.1016/0022-3913(89)90170-4
  25. Flugge TV, Schlager S, Nelson K, Nahles S, Metzger MC. Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner. Am J Orthod Dentofacial Orthop 2013;144:471-8. https://doi.org/10.1016/j.ajodo.2013.04.017
  26. Vojdani M, Torabi K, Farjood E, Khaledi A. Comparison the marginal and internal fit of metal copings cast from wax patterns fabricated by CAD/CAM and conventional wax up techniques. J Dent (Shiraz) 2013;14:118-29.
  27. McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J 1971;131:107-11. https://doi.org/10.1038/sj.bdj.4802708
  28. Fransson B, Oilo G, Gjeitanger R. The fit of metal-ceramic crowns, a clinical study. Dent Mater 1985;1:197-9. https://doi.org/10.1016/S0109-5641(85)80019-1
  29. Moldovan O, Rudolph H, Quaas S, Bornemann G, Luthardt RG. Internal and external fit of CAM-made zirconia bridge frameworksa pilot study. Dtsch Zahnarztl Z 2006;61:38-42.
  30. Sakrana AA. In vitro evaluation of the marginal and internal discrepancies of different esthetic restorations. J Appl Oral Sci 2013;21:575-80. https://doi.org/10.1590/1679-775720130064
  31. Sorensen JA. A standardized method for determination of crown margin fidelity. J Prosthet Dent 1990;64:18-24. https://doi.org/10.1016/0022-3913(90)90147-5
  32. Molin M, Karlsson S. The fit of gold inlays and three ceramic inlay systems. A clinical and in vitro study. Acta Odontol Scand 1993;51:201-6. https://doi.org/10.3109/00016359309040568
  33. Kokubo Y, Nagayama Y, Tsumita M, Ohkubo C, Fukushima S, Vult von Steyern P. Clinical marginal and internal gaps of In-Ceram crowns fabricated using the GN-I system. J Oral Rehabil 2005;32:753-8. https://doi.org/10.1111/j.1365-2842.2005.01506.x
  34. Colpani JT, Borba M, Della Bona A. Evaluation of marginal and internal fit of ceramic crown copings. Dent Mater 2013;29:174-80. https://doi.org/10.1016/j.dental.2012.10.012

Cited by

  1. Extraoral scanner와 intraoral scanner를 이용하여 제작된 zirconia crown의 2차원 변연 및 내면 적합도 비교: in vitro vol.41, pp.3, 2017, https://doi.org/10.14347/kadt.2019.41.3.187