DOI QR코드

DOI QR Code

Comparison of Reduction Reactivity of New Oxygen Carriers for Chemical Looping Combustion System in a Bubbling Fluidized Bed

기포유동층에서 케미컬루핑 연소시스템을 위한 신규 산소전달입자들의 환원반응성 비교

  • Received : 2017.07.29
  • Accepted : 2017.08.30
  • Published : 2017.10.30

Abstract

Reduction reactivity of new oxygen carriers for chemical looping combustion system were investigated using $CH_4$ as a reduction gas in a bubbling fluidized bed reactor and compared with that of former SDN70 oxygen carrier. New oxygen carriers showed good reduction reactivity at different $CH_4$ concentration. N018-R2 particle represented better reactivity than SDN70 at high $CH_4$ concentration. N018-R2 particle showed higher fuel conversion and $CO_2$ selectivity than those of SDN70 particle within the temperature range of $750-900^{\circ}C$. Moreover, attrition loss of N018-R2 particle was almost same with that of SDN70 particle. Consequently, we could select N018-R2 particle as the best oxygen carrier.

Keywords

References

  1. J. Adanez, A. Abad, F. Garcia-Labiano, P. Gayan, and L. F. de Diego, "Progress in Chemical Looping Combustion and Reforming Technology", Progress in Energy and Combustion Science, Vol. 38, 2012, pp. 215-282. https://doi.org/10.1016/j.pecs.2011.09.001
  2. Q. Guo, X. Hu, Y. Liu, W. Jia, M. Yang, M. Wu, H. Tian, and H. J. Ryu, "Coal Chemical-looping Gasification of Ca-based Oxygen Carriers Decorated by CaO", Powder Technology, Vol. 275, 2015, pp. 60-68. https://doi.org/10.1016/j.powtec.2015.01.061
  3. H. J. Ryu, K. S. Kim, Y. S. Park, and M. H. Park, "Natural Gas Combustion Characteristics of Mass Produced Oxygen Carrier Particles for Chemicallooping Combustor in a Batch Type Fluidized Bed Reactor", Trans. of the Korean Society of Hydrogen Energy, Vol. 20, No. 2, 2009, pp. 151-160.
  4. H. J. Ryu, N. Y. Lim, D. H. Bae, and G. T. Jin, "Minimum Fluidization Velocity and Transition Velocity to Fast Fluidization of Oxygen Carrier Particle for Chemical Looping Combustor", HWAHAK KONGHAK, Vol. 41, No. 5, 2003, pp. 624-631.
  5. H. Kim, D. H. Lee, J. I. Baek, and H. J. Ryu, "Selection of Oxygen Carrier Candidates for Chemical Looping Combustion by Measurement of Oxygen Transfer Capacity and Attrition Loss", Trans. of the Korean Society of Hydrogen Energy, Vol. 27, No. 4, 2016, pp. 404-411. https://doi.org/10.7316/KHNES.2016.27.4.404
  6. H. J. Ryu, Y. Park, S. Y. Lee, S. H. Jo, D. Shun, and J. I. Baek, "CH4 Combustion Characteristics of Oxygen Carrirs in a Bubbling Fluidized Bed". Trans. of the Korean Society of Hydrogen Energy, Vol. 27, No. 5, 2016, pp. 581-588. https://doi.org/10.7316/KHNES.2016.27.5.581
  7. J. Y. Yoon, D. H. Bae, J. I. Baek, and H. J. Ryu, "Reduction Characteristics of Oxygen Carriers in a Pressurized Bubbling Fluidized Bed", Trans. of the Korean Society of Hydrogen Energy, Vol. 27, No. 5, 2016, pp. 589-596. https://doi.org/10.7316/KHNES.2016.27.5.589
  8. J. I. Baek, S. R. Yang, T. H. Eom, J. B. Lee, and C. K. Ryu, "Effect of MgO addition on the physical properties and reactivity of the spray dried oxygen carriers prepared with a high content oof NiO and $Al_2O_3$", Fuel, Vol. 144, 2015, pp. 317-326. https://doi.org/10.1016/j.fuel.2014.11.035
  9. H. J. Ryu, D. H. Lee, S. Y. Lee, and G. T. Jin, "Attrition Characteristics of WGS Catalysts for SEWGS System", Trans. of the Korean Society of Hydrogen Energy, Vol. 25, No. 2, 2014, pp. 122-130. https://doi.org/10.7316/KHNES.2014.25.2.122