DOI QR코드

DOI QR Code

Apnea Detection and Respiration Rate Estimation Using IR-UWB Radar Signals

IR-UWB 레이다 기반의 무호흡 검출 및 호흡수 측정

  • Ko, Inchang (Dept. of Interdisciplinary Bio IT Materials, Seoul National University of Science and Technology) ;
  • Park, Hyung Chul (Dept. of Electronic and IT Media Engineering, Seoul National University of Science and Technology)
  • 고인창 (서울과학기술대학교 바이오IT소재 융합 협동과정) ;
  • 박형철 (서울과학기술대학교 전자IT미디어공학과)
  • Received : 2017.08.14
  • Accepted : 2017.10.18
  • Published : 2017.10.31

Abstract

This paper presents a novel apnea detection and respiration rate estimation method using impulse-radio ultra-wideband (IR-UWB) radar. The proposed method utilizes amplitude, time of arrival, and power in the selected band. The experimental results show that respiration rate can be estimated accurately using proposed method. And, it is shown that the selectivity between apnea and respiration can be improved more than 50 dB using the proposed method.

본 논문에서는 IR-UWB 레이다 신호를 이용하여 무호흡 검출과 호흡수를 측정할 수 있는 방법을 제안한다. 제안한 방법에서는 무호흡 검출과 호흡수 측정을 동시에 지원하기 위해서 레이다 신호의 크기, 도래시간 및 선택된 주파수 대역에서의 전력 정보를 이용한다. 하드웨어 실험을 통해서 제안한 방법을 사용하여 정확한 호흡수 측정이 가능함을 보인다. 또한, 제안한 방법을 사용하여 무호흡과 호흡의 선택비가 최소 50 dB 이상이 됨을 보인다.

Keywords

References

  1. Richard B. Berry, Rohit Budhiraja, Daniel J. Gottlieb, David Gozal, Conrad Iber, Vishesh K. Kapur, Carole L. Marcus, Reena Mehra, Sairam Parthasarathy, Stuart F. Quan, Susan Redline, Kingman P. Strohl, Sally L. Davidson Ward, and Michelle M. Tangredi., "Rules for scoring respiratory events in sleep: Update of the 2007 AASM manual for the scoring of sleep and associated events", J. Clin. Sleep Med, vol. 8, no. 5, pp. 597-619, 2012. https://doi.org/10.5664/jcsm.2172
  2. G. T. O'Connor, B. Caffo, A. B. Newman, S. F. Quan, D. M. Rapoport, S. Redline, H. E. Resnick, J. Samet, and E. Shahar, "Prospective study of sleep-disordered breathing and hypertension: the sleep heart health study", American Journal of Respiratory and Critical Care Medicine, vol. 179, no. 12, pp. 1159-1164, 2009. https://doi.org/10.1164/rccm.200712-1809OC
  3. D. J. Gottlieb, G. Yenokyan, A. B. Newman, G. T. O'Connor, N. M. Punjabi, S. F. Quan, S. Redline, H. E. Resnick, E. K. Tong, M. Diener-West, and E. Shahar, "Prospective study of obstructive sleep apnea and incident coronary heart disease and heart failure the sleep heart health study", Circulation, vol. 122, no. 4, pp. 352-360, 2010. https://doi.org/10.1161/CIRCULATIONAHA.109.901801
  4. R. Ruangsuwana, G. Velikic, and M. Bocko, "Methods to extract respiration information from ECG signals", Proc. IEEE Int. Conf. Acoust. Speech Signal Process, pp. 570-573, Mar. 2010.
  5. P. De Chazal, C. Heneghan, E. Sheridan, R. Reilly, P. Nolan, and M. O'Malley, "Automated processing of the single-lead electrocardiogram for the detection of obstructive sleep apnea", IEEE Trans. on Bio. Eng., vol. 50, no. 6, pp. 686-696, 2003. https://doi.org/10.1109/TBME.2003.812203
  6. A. H. Khandoker, M. Palaniswami, and C. K. Karmakar, "Support vector machines for automated recognition of obstructive sleep apnea syndrome from ecg recordings", IEEE Trans. on Information Tech. in Biomedicine, vol. 13, no. 1, pp. 37.48, 2009. https://doi.org/10.1109/TITB.2008.2004495
  7. D. Pevernagie, R. M. Aarts, and M. De Meyer, "The acoustics of snoring", Sleep Medicine Reviews, vol. 14, no. 2, pp. 131-144, 2010. https://doi.org/10.1016/j.smrv.2009.06.002
  8. M. Kagawa, K. Ueki, H. Tojima, and T. Matsui, "Noncontact screening system with two microwave radars for the diagnosis of sleep apneahypopnea syndrome", Proc. 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, pp. 2052-2055, Jul. 2013.
  9. Y. S. Lee, P. Pathirana, C. Steinfort, and T. Caelli, "Monitoring and analysis of respiratory patterns using microwave Doppler radar", IEEE J. of Trans. Eng. in Health and Medicine, vol. 2, pp. 1-12, 2014.
  10. J.-M. Kang, D.-W Lim, J.-H. Lee, C. In, H.-M. Kim, S.-C. Woo, and C. Kim, "Reliable estimation of respiration rate using UWB impulse radar", Proc. 2013 Asia- Pacific Microwave Conf., pp. 997-999, Nov. 2013.
  11. S. Wu, S. Yao, W. Liu, K. Tan, Z. Xia, S. Meng, J. Chen, G. Fang, and H. Yin, "Study on a novel UWB linear array human respiration model and detection nethod", IEEE J. Sel. Topics Appl. Earth Observ. Remote Sens., vol. 9, no. 1, pp. 125-140, Jan. 2016. https://doi.org/10.1109/JSTARS.2016.2519760
  12. G. Fedele, E. Pittella, S. Pisa, M. Cavagnaro, R. Canali, M. Biagi, "Sleep-apnea detection with UWB active sensors", Proc. IEEE Int. Conf. on Ultra-Wideband, pp. 1-5, Oct. 2015.
  13. A. Q. Javaid, C. M. Noble, R. Rosenberg, and M. A. Weitnauer, "Towards sleep apnea screening with an under-the-mattress IR-UWB radar using machine learning", Proc. IEEE Int. Conf. on Machine Learning and Applications, pp. 837-842, Dec. 2015.
  14. R. Zetik, J. Sachs, and R. S. Thoma, "UWB short-range radar sensing", IEEE Instru. Meas. Mag., vol. 10, no. 2, pp. 39-45, Apr. 2007. https://doi.org/10.1109/MIM.2007.364960
  15. D. Zito, D. Pepe, M. Mincica, F. Zito, A. Tognetti, A. Lanata, and D. De Rossi, "SoC CMOS UWB pulse radar sensor for contactless respiratory rate monitoring", IEEE Trans. Biomed. Circuits Syst., vol. 5, no. 6, pp. 503-510, Dec. 2011. https://doi.org/10.1109/TBCAS.2011.2176937
  16. S. Venkatesh, C. R. Anderson, N. V. Rivera, and R. M. Buehrer, "Implementation and analysis of respirationrate estimation using impulse-based UWB", Proc. IEEE Military Communications Conference (MILCOM), pp. 3314-3320, Oct. 2005.