References
- Piesch E, Burgkhardt B, Fischer M, Rober HG, Ugi S, "Properties of radiophotoluminescencent glass dosemeter systems using pulsed laser UV excitation," Radiat Prot Dosim, vol. 17, pp. 293-297, 1986. https://doi.org/10.1093/oxfordjournals.rpd.a079826
- Burgkhardt B, Festag JG, Piesh E, Ugi S, "New aspects of environmental monitoring using flat phosphate glass and thermoluminescence dosemeters," Radiat Prot Dosim, vol. 66, no. 1, pp. 187-192, 1996. https://doi.org/10.1093/oxfordjournals.rpd.a031713
- Asahi Techno Glass Corporation. Technical information for RPL glass dosemeter type SC-1. Tokyo, Japan, 2000.
- Piesch E, Burgkhardt B, Vilgis M, "Photoluminescence dosimetry: progress and present state of art," Radiat Prot Dosim, vol. 33, no. 1-4, pp. 215-226, 1990. https://doi.org/10.1093/oxfordjournals.rpd.a080796
- Knezevi Z, Beck N, Milkovi , Miljani S, Ranogajec- Komor M, "Characterisation of RPL and TL dosimetry systems and comparison in medical dosimetry applications," Radiat Mes, vol. 46, pp. 1582-1585, 2011. https://doi.org/10.1016/j.radmeas.2011.05.042
- Rah EJ, Hong JY, Kim GY, Kim YL, Shin DO, Suh TS, "A comparison of the dosimetric characteristics of a glass rod dosimeter and a thermoluminescent dosimeter for mailed dosimeter," Radiat Meas, vol. 44 no. 1, pp. 18-22, 2009. https://doi.org/10.1016/j.radmeas.2008.10.010
- Araki F, Ikegami T, Ishidoya T, Kubo HD, "Measurements of gamma-knife helmet output factors using a radiophotoluminescent glass rod dosimeter and a diode detector," Med Phys, vol. 30, no. 8, pp. 1976-1981, 2003. https://doi.org/10.1118/1.1587451
- Lee JH. Lin MS, Hsu SM, Chen IJ, Chen WL, Wang CF, "Dosimertry characteristics and performance comparisons: Environmental radiophotoluminescent glass dosemeters versus thermoluminescent dosemeters," Radiat Meas, vol. 44, pp. 86-91, 2009. https://doi.org/10.1016/j.radmeas.2008.10.013
- Asahi Techno Glass Corporation. New RPL glass dosemeter system for large scale personal monitoring. Tokyo, Japan, 2001.
- Hsu SM, Yeh SH, Lin MS, Chen WL, "Comparison on characteristics of radiophotoluminescent glass dosemeters and thermoluminescent dosemeters," Radiat Prot Dosim, vol. 119, pp. 327-331, 2006. https://doi.org/10.1093/rpd/nci510
- Rah JE, Shin DO, Hong JY, Kim HS, Lim CI, Jeong HG, Suh TS, "Study on dosimetric properties of radiophotoluminescent glass rod detector," J Korea Asso Radiat Prot, vol. 31, no. 4, pp. 181-186, 2006.
- Son JH, Kim SH, Mun HH, Kim LK, Son IH, Kim YJ, Min JW, Kim KW, "A study on characteristic of glass dosimeter according to graded change of tube current," J Radiol Sci Technol, vol. 37, no. 2, pp. 135-141, 2014.
- Lim SN, Pradhan AK, Barth RF, Nahar SN, Nakkula RJ, Yang W, Palmer AM, Turro C, Weldon M, Bell EH, Mo X, "Tumoricidal activity of low-energy 160-kV versus 6-MV Xrays against platinum-sensitized F98 glioma cells," J Radiat Res, vol. 56, no. 1, pp. 77-89, 2015. https://doi.org/10.1093/jrr/rru084