DOI QR코드

DOI QR Code

P-value significance level test for high-performance steel fiber concrete (HPSFC)

  • Abubakar, Abdulhameed U. (Department of Civil Engineering, Eastern Mediterranean University (EMU)) ;
  • Akcaoglu, Tulin (Department of Civil Engineering, Eastern Mediterranean University (EMU)) ;
  • Marar, Khaled (Department of Civil Engineering, Eastern Mediterranean University (EMU))
  • Received : 2017.08.15
  • Accepted : 2018.01.08
  • Published : 2018.05.25

Abstract

Statistical analysis has found useful application in the design of experiments (DOE) especially optimization of concrete ingredients however, to be able to apply the concept properly using computer aided applications there has to be an upper and lower limits of responses fed to the system. In this study, the production of high-performance steel fiber concrete (HPSFC) at five different fiber addition levels by volume with two aspect ratios of 60 and 83 were studied under two curing methods completely dry cured (DC) and moist cured (MC) conditions. In other words, this study was carried out for those limits based on material properties available in North Cyprus. Specimens utilized were cubes 100 mm size casted and cured for 28 days and tested for compressive strength. Minitab 18 statistical software was utilized for the analysis of results at a 5 per cent level of significance. Experimentally, it was observed that, there was fluctuation in compressive strength results for the two aspect ratios and curing regimes. On the other hand P-value hypothesis evaluation of the response showed that at the stated level of significance, there was a statistically significant difference between dry and moist curing conditions. Upper and lower limit values were proposed for the response to be utilized in DOE for future studies based on these material properties. It was also suggested that for a narrow confidence interval and accuracy of the system, future study should increase the sample size.

Keywords

References

  1. Abdullahi, M., Al-Mattarneh, H.M.A. and Mohammed, B.S. (2009a), "Statistical modelling of lightweight concrete mixtures", Eur. J. Scientif. Res., 31(1), 124-131.
  2. ACI544.4R-08 (1999), Design Considerations for Steel Fiber Reinforced Concrete, American Concrete Institute, Farmington Hills, MI, USA.
  3. ACI544.3R-08 (2015), Guide for Specifying, Proportioning, and Production of Fiber-Reinforced Concrete, American Concrete Institute, Farmington Hills, MI, USA.
  4. Ahmad, S. and Alghamdi, S.A. (2014), "A statistical approach to optimizing concrete mixture design", Sci. World J., 2014, Article ID 561539.
  5. Aitcin, P.C. (1998), High-Performance Concrete, E & FN SPON, New York, NY, USA.
  6. ASTM A820 (2011), Standard Specification for Steel Fibers for Fiber Reinforced Concrete, ASTM International, West Conshohocken, PA, USA.
  7. ASTM C117-13 (2013), Standard Test Method for Materials Finer than 75-${\mu}m$ (No. 200) Sieve in Mineral Aggregates by Washing., ASTM International, West Conshohocken, PA.
  8. ASTM C595/C595M-17 (2017), Standard Specification for Blended Hydraulic Cements, ASTM International, West Conshohocken, PA, USA.
  9. ASTM C494/C494M-17 (2017), Standard Specification for Chemical Admixtures for Concrete, ASTM International, West Conshohocken, PA.
  10. ASTM C33/C33M-16e1 (2016), Standard Specification for Concrete Aggregates, ASTM International, West Conshohocken, PA.
  11. ASTM C136/C136M-14 (2014), Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates, ASTM International, West Conshohocken, PA.
  12. ASTM C127-15 (2015), Standard Test Method for Relative Density (Specific Gravity) and Absorption of Coarse Aggregate, ASTM International, West Conshohocken, PA.
  13. ASTM C128-15 (2015), Standard Test Method for Relative Density (Specific Gravity) and Absorption of Fine Aggregate, ASTM International, West Conshohocken, PA.
  14. ASTM C29/C29M-17a (2017), Standard Test Method for Bulk Density ("Unit Weight") and Voids in Aggregate, ASTM International, West Conshohocken, PA.
  15. ASTM C29/C29M-17a (2017), Standard Test Method for Bulk Density ("Unit Weight") and Voids in Aggregate, ASTM International, West Conshohocken, PA.
  16. Aydin, E. (2017a), "Data for the physical and mechanical properties of staple fibers cement paste composites", Data Brief, 14, 307-312. https://doi.org/10.1016/j.dib.2017.07.055
  17. Aydin, E. (2017b), "Staple wire-reinforced high-volume fly-ash cement paste composites", Constr. Build. Mater., 153(3), 393-401. https://doi.org/10.1016/j.conbuildmat.2017.07.125
  18. BS 882:Part 2 (1992), Specification for Aggregates from Natural Sources for Concrete, British Standard Institution, BSI, London.
  19. BS EN 1008 (2002), Mixing Water for Concrete, Specification for Sampling, Testing and Assessing the Suitability of Water, Including water recovered from processes in the concrete industry, as Mixing Water for Concrete, British Standard Institution, BSI, London.
  20. BS EN 12390-3 (2009), Testing Hardened Concrete, Compressive Strength of Test Specimens, British Standard Institution, BSI, London.
  21. Celik, T. and Marar, K. (1996), "Effects of crushed stone dust on some properties of concrete", Cement Concrete Res., 26(7), 1121-1130. https://doi.org/10.1016/0008-8846(96)00078-6
  22. Diah, Md. J., Ahmad, J. and Mukri, M. (2012), "The methodology on statistical analysis of data transformation for model development", Int. J. Statist. Appl., 2(6), 94-100. https://doi.org/10.5923/j.statistics.20120206.01
  23. Eren, O . and Celik, T. (1997), "Effect of silica fume and steel fibers on some properties of high-strength concrete", Constr. Build. Mater., 11(97), 373-382. https://doi.org/10.1016/S0950-0618(97)00058-5
  24. Eren, O ., Marar, K. and Celik, T. (1999), "Effects of silica fume and steel fibers on some mechanical properties of high-strength fiber-reinforced concrete", J. Test. Eval., 27, 380-387. https://doi.org/10.1520/JTE12166J
  25. Khaloo, A.R. and Kim, N. (1996), "Mechanical properties of normal to high-strength steel fiber-reinforced concrete", Cement Concrete Aggregat., CCAGDP, 18(2), 92-97. https://doi.org/10.1520/CCA10156J
  26. Kosmatka, S.H. and Panarese, W.C. (1988), Design and Control of Concrete Mixtures, Thirteenth Edition. Skokie, Portland Cement Association, Illinois.
  27. Lloyd, M. (2014) "2-Sample t-distribution approximation", Acad. Forum, 31, 23-30.
  28. Marar, K., Eren, O. and Yitmen, I. (2011), "Compression specific toughness of normal strength steel fiber reinforced concrete (NSSFRC) and high strength steel fiber reinforced concrete (HSSFRC)", Mater. Res., 14(2), 239-247. https://doi.org/10.1590/S1516-14392011005000042
  29. Marar, K., Eren, O . and Roughani, H. (2016), "The influence of amount and aspect ratio of fibers on shear behaviour of steel fiber reinforced concrete", KSCE J. Civil Eng., 21(4), 1393-1399.
  30. Minitab 18 (2017), http://www.minitab.com/en-us/
  31. Mosaberpanah, M.A. and Eren, O. (2016), "Statistical flexural toughness modeling of ultra high performance concrete using response surface method", Comput. Concrete, 17(4), 1-12. https://doi.org/10.12989/cac.2016.17.1.001
  32. Simon, M., Lagergren, E.S. and Snyder, K.A. (1997), "Concrete mixture optimization using statistical mixture design methods", Proceedings of the PCI/FHWA International Symposium on High Performance Concrete New Orleans, October.
  33. Tirkolaei, H.K. and Bilsel, H. (2015), "Statistical modeling of environmental factors on microbial urea hydrolysis process for biocement production", Adv. Mater. Sci. Eng., 2015, Article ID 340930.
  34. Walpole, R.E., Myers, R.H., Myers, S.L. and Ye, K. (2012), Probability & Statistics for Engineers & Scientists, Prentice Hall.

Cited by

  1. Influence of pre-compression on crack propagation in steel fiber reinforced concrete vol.11, pp.3, 2021, https://doi.org/10.12989/acc.2021.11.3.261