A experimental Study on Insulation Breaking Fire Case of Starter Motor B Terminal

스타트모터 B단자 절연파괴 화재사례에 대한 실험적 연구

  • Woo, Seung Woo (Department of Physical Engineering, National Forensic Service Seoul Institute) ;
  • Park, J.M. (Department of Physical Engineering, National Forensic Service Seoul Institute) ;
  • Hyun, B.S. (Department of Physical Engineering, National Forensic Service Seoul Institute) ;
  • Nam, J.W. (Department of Physical Engineering, National Forensic Service Seoul Institute) ;
  • Park, W.S. (Department of Physical Engineering, National Forensic Service Seoul Institute) ;
  • Kim, J.P. (National Forensic Service Daejeon Institute) ;
  • Cho, Y.J. (Department of Forensic Safety, National Forensic Service) ;
  • Goh, J.M. (Department of Forensic Safety, National Forensic Service) ;
  • Park, N.K. (Department of Forensic Safety, National Forensic Service)
  • 우승우 (국립과학수사연구원 서울과학수사연구소 이공학과) ;
  • 박정만 (국립과학수사연구원 서울과학수사연구소 이공학과) ;
  • 현병수 (국립과학수사연구원 서울과학수사연구소 이공학과) ;
  • 남정우 (국립과학수사연구원 서울과학수사연구소 이공학과) ;
  • 박우식 (국립과학수사연구원 서울과학수사연구소 이공학과) ;
  • 김진표 (국립과학수사연구원 대전과학수사연구소) ;
  • 조영진 (국립과학수사연구원 법안전과) ;
  • 고재모 (국립과학수사연구원 법안전과) ;
  • 박남규 (국립과학수사연구원 법안전과)
  • Received : 2019.09.24
  • Accepted : 2019.10.24
  • Published : 2019.10.31

Abstract

In this paper, we introduce a case of a fire accident during parking of a large truck that is repeatedly occurring. The shape and location of the combustion and electrical singularity commonly found in other vehicle fire accidents could limit the starter motor as the ignition section. In addition, it was possible to confirm the electrical melting singularity that could act as a cause of ignition between the start motor B terminal and the start motor enclosure. By combining the above investigations and investigations, it was possible to estimate the electric fire expressed from insulation breaking of the starter motor B terminal, and by using the renewable starter motor comparison product mounted on the fire vehicle, an experiment was performed to reproduce the ignition process from the starter motor under specific conditions. So. It is hoped that this will raise awareness about vehicle fires, which can lead to large fires or casualties, share the risks of using starter motors for regeneration, and help in the rapid and accurate investigation of similar vehicle fires in the future.

Keywords

References

  1. National Fire Data System Korea, 2016 Fire Statistics, 2016. http://www.index.go.kr
  2. E. Lee, "A Study on Analysis on an Automotive Fire Case that Broke Out Due to an Electrical Cause during Engine Stopping", Trans. of Korean Society of Automotive Engineering, Vol. 21, No. 1, pp. 9-16, 2013. https://doi.org/10.7467/KSAE.2013.21.1.009
  3. National Fire Protection Association, "NFPA 921 Guide for Fire and Explosion Investigation", 2008 Edition, pp. 189-200, 2008.
  4. N. K. Park et al., "Analysis on Vehicle Fires Caused by Defect of Optionally Established Equipment", J. Korean Soc. Saf., Vol. 29, No. 5, pp. 40-46, 2014. https://doi.org/10.14346/JKOSOS.2014.29.5.040
  5. N. K. Park et al., "Analysis on Vehicle Fires Caused by Damage of the Vehicle's Electrical Components", J. Korean Soc. Saf., Vol. 30, No. 4, pp. 32-38, 2015. https://doi.org/10.14346/JKOSOS.2015.30.4.32