A Study on the optimized Performance Designing of the Window of the Apartment based on the Annual Energy Demand Analysis according to the Azimuth Angle applying the Solar Heat Gain Coefficient of the Window

창호에 SHGC를 반영한 공동주택의 방위각별 에너지 효율성 평가를 통한 합리적인 창호 계획 방안 연구

  • 이장범 (선문대 건축사회환경공학부)
  • Received : 2019.08.04
  • Accepted : 2019.11.10
  • Published : 2019.11.30

Abstract

It is important to design windows in a reasonable way considering the performance characteristics of the elements of the window rather than just to increase the thermal energy performance of the window. In this study, the Heat-transfer Coefficient as insulation performance of the windows and together with the grade of the glass's SHGC (Solar Heat Gain Coefficient) were analyzed to relate to the energy efficiency performance of the building by azimuth angle. Based on this basic study, the Heat-transfer Coefficient of windows and the SHGC rating of glass were applied to the unit plan of apartment building, and the Heating and Cooling Demand were analyzed by azimuth angle. Apartment plan types were divided into 2 types of Non-extension and extension of balcony. The designPH analysis data derived from the variant of the Heat-transfer Coefficient and SHGC, were put into PHPP(Passive House Planning Package) to analyze precisely the energy efficiency(Heating and Cooling Demands) of the building by azimuth angle. In addition, assuming the 'ㅁ' shape layout, energy efficiency performance and potential of PV Panel installation also were analyzed by floors and azimuth angle, reflecting the shading effects by surrounding buildings. As the results of the study, the effect of Heat Gain by SHGC was greater than Heat Loss due to the Heat-transfer Coefficient. So it is more effective to increase SHGC to satisfy the same Heating Demand, and increasing SHGC made possible to design windows with low Heat-transfer Coefficient. It was also revealed that the difference in annual Heating and Cooling Demands between the low, mid and high floor households is significantly high. In addition to it, the installation of PV Panel in the form of a shading canopy over the window reduces the Cooling Load while at the same time producing electricity, and also confirmed that absolute thermal energy efficiency could not be maximized without controlling the thermal bridge and ventilation problems as important heat loss factors.

Keywords

References

  1. Cho, S., Park, J., & Hong, W. (2017). Reproducibility Evaluation Study of Thermal Resistance Test for Windows and Doors, Journal of the Architectural Institute of Korea, Planning and Design Section, 33(7), 63-71 https://doi.org/10.5659/JAIK_PD.2017.33.1.63
  2. Choe, Y., & Jo, J. (2013). Calculation Method of Window Energy Performance considering Heating and Cooling Load in Multi-family Housing, Journal of the Architectural Institute of Korea, Planning and Design Section, 29(12), 277-286
  3. Park, Y., Park, J., & Lee, E. (2011). Evaluation of Thermal Performance by Glazing in the Expanded Balcony of Apartment House, Proceeding of Spring Conference of the Architectural Institute of Korea, Planning and Design Section, 31(1), 201-202
  4. Kwak, I., Kim, G., Mun, S., & Huh, J. (2017). Parametric Analysis of Building Energy Impact of Semi-transparent PV, Proceeding of Spring Conference of the Architectural Institute of Korea, 37(2), 531-543
  5. Park, J., Kang, S., & Kim, K. (2013). The Evaluation of U-value and Heating & Cooling Energy Performance of Vacuum glazing window, Proceeding of Spring Conference of the Architectural Institute of Korea, 33(1), 265-266
  6. Kim, D., Youn, J., Shin, U., & Kwak, H. (2012). A study on the annual energy performance of apartment building with the equivalent U-value od envelope considering the effect ot thermal bridges. Journal of the KIEAE, Vol. 12 No. 3, 41-46
  7. Kwak, H., Jang, H., Lee, H., Eom, J., & Seo, S. (2013). Corelation Analysis Between Fenestration Energy Consumption Effincicy Rating System and Building Consumption, Korea Journal of Air-Conditioning and Refrigeration Engineering, Vol. 25 No. 6, 338-345 https://doi.org/10.6110/KJACR.2013.25.6.338
  8. Lim, H., Kim, D., Lee, S., An, J., Yoon, J., & Shin, U. (2018). Energy Performance Evaluation of Apartment Houses According to Window Energy Consumption Efficiency Rating System in Korea, Korea Journal of Air-Conditioning and Refrigeration Engineering, Vol. 30 No. 4, 159-166 https://doi.org/10.6110/KJACR.2018.30.4.159
  9. Sergio G., Lucie K., Giuseppe P., & Peter S. (2010). Building Energy Efficiency, IUSES
  10. Jennifer G., Jim B., Jeff H., Sarah S., Steve B., Kathryn F., & Janet B. (2010). WHAT IS PASSIVHAUS?, Dovetail Partners Inc.
  11. Lee, J. (2016). A Study on the analysis of the effective installation position for the photovoltaic and the various design application in the apartment complex. Journal of the Architectural Institute of Korea, Planning and Design Section, 32(12) 47-54
  12. Hong, D. (2013). Window with relation to energy efficiency, 3rd Passive house seminar, Passive House Institute Korea
  13. Youn, Y. (2011). Insulation and window technique for Passive house, Passive House Institute Korea Opening Conference, Passive House Institute Korea
  14. http://www.phiko.kr/bbs/board.php?bo_table=z3_01&wr_id=599
  15. Hanglass (2019). Power Catalogue, Hankuk Glass Industries Inc.