DOI QR코드

DOI QR Code

Comparison of the Effect of Ultrafine Dust According to the Shape of Main Lobby Space of General Hospital - Focusing on Area, Height, X/Y Ratio of Lobby Space -

종합병원 주출입부 로비공간 규모 및 형태에 따른 초미세먼지 영향 비교 - 로비 면적, 높이, X/Y축 비율을 중심으로 -

  • 윤은지 (홍익대학교 일반대학원 건축학과) ;
  • 임영환 (홍익대학교 건축대학)
  • Received : 2020.09.09
  • Accepted : 2020.11.11
  • Published : 2020.11.30

Abstract

General hospitals are used by many, including patients and visitors that are physically vulnerable to fine dust. Passive planning with the spatial structure of hospitals to cope with fine dust should be considered, in terms of public health, climate adaptation and sustainability. The purpose of this study is to compare the shape and volume of a lobby space that is advantageous in reducing the influx and influence of external fine dust in the main lobby space of a general hospital. In this study, ultrafine dust(PM2.5), which can adversely affect health, was targeted. Based on the morphological classification of lobby spaces in general hospitals in the preceding study, the spread of PM2.5 in lobby spaces was investigated through simulation. The lobby and the elevator hall through which fine dust can spread throughout the building were covered in the simulation. The results are as follow. If the other conditions are the same, the amount of PM2.5 reaching the elevator hall slightly decreased as the lobby area increased, and it significantly decreased as the height of the lobby increased. In the case of the same area and height of the lobby, when the X-axis length was longer than the Y-axis length, the amount of ultrafine dust reaching the elevator hall was less. It implies that the direction of the incoming air with dust and the spatial axis is closely related, and the follow-up study should be conducted including variables such as climatic conditions, direction of openings, and spatial axis.

Keywords

Acknowledgement

이 논문은 2019년도 정부(과학기술정보통신부)의 재원으로 한국연구재단의 지원을 받아 수행된 연구임 (No. NRF-2019R1F1A1059796)

References

  1. Back, J., Yee, S., Lee, B., Kang, D., Yeo, M., & Kim, K. (2015). A study on the relationship between the indoor and outdoor particulate matter concentration by infiltration in the winter. Journal of the Architectural Institute of Korea Planning & Design, 31(9), 138-139.
  2. Choi, D., & Kang, D. (2013). Experimental and computational fluid dynamics (CFD) methods to analyze particle resuspension and dispersion in buildings. Journal of the Architectural Institute of Korea Planning & Design, 29(10), 275-276. https://doi.org/10.5659/JAIK_PD.2013.29.10.275
  3. Choi, I., & Park, H. (2017). Analysis of the spatial configuration of lobby in general hospital. Journal of the Korean Institute of Interior Design, 26(1), 135-136.
  4. Diapouli, E., Chaloulakou, A., & Koutrakis, P. (2013). Estimating the concentration of indoor particles of outdoor origin: A review. Journal of the Air & Waste Management Association, 63(10), 1119.
  5. Jeong, K. (2019). 2019 Report on evaluation results of regional public hospitals. National Medical Center. Retrieved from https://www.ppm.or.kr/board/fileList.do
  6. Lee, B. (2017). Assessment of outdoor particle penetration and transport in a building using multi-zone model (Doctoral dissertation, The Graduate School of Seoul National University), 22, 102. Retrieved from http://s-space.snu.ac.kr/handle/10371/136704
  7. Lee, B., Yee, S., Kang, D., Yeo, M., & Kim, K. (2017). Multi-zone simulation of outdoor particle penetration and transport in a multi-story building. Building Simulation, 10(4), 526, 531. Tsinghua University Press.
  8. Lee, K., Yeom, J., Lee, W., Ryu, S., Park, D., & Park, D. (2014). An assessment of environmental characteristics associated with the level of endotoxin concentration in hospital lobbies. Journal of Korean Society of Occupational and Environmental Hygiene, 24(3), 311.
  9. Lee, Y., & Oh, J. (2018). Healing environment at the general hospital lobby space -by comparison of the lobby plan type. Journal of the Korea Academia-Industrial cooperation Society, 19(5), 91.
  10. Lim, T., Kang, S., & Kim, B. (2009). A Inquiry of Tracer Gas for Analysis of Dispersion and Prediction of Infection Possibility according to Airborne Viral Contaminants. Journal of the Korean Institute of Interior Design, 18(3), 105.
  11. Myong, J. (2016). Health rffects of particulate matter. The Korean Journal of Medicine, 91(2), 108-111. https://doi.org/10.3904/kjm.2016.91.2.106
  12. Phyo, J., & Yang, N. (2002). A Study on the conceptual change and utilization of the lobby space in general hospitals. Journal of the Korean Institute of Interior Design, 34(10), 87-91,
  13. Son, J., & Yang, N. (2014). A study on the change of paradigm and analysis of qualitative space in public space focused on the entrance floor in general hospital over 500 beds in Korea. Journal of the Korean Institute of Interior Design, 23(6), 215-216.
  14. Yoon, E. (2020). Regional type classification considering the trend of changes in PM10 concentration. Sejong, KRIHS, 26.
  15. Yoon, E., & Lim, Y. (2020). Study on categorization of hospital exterior Space - Considering the changed value of exterior space due to fine dust. Journal of the Architectural Institute of Korea Planning & Design, 36(7), 22.