Validation on Performance of Soil Moisture Sensor using Weighing Porous Ceramic Cone Filled with Soil

다공질 세라믹 추를 이용한 중량 토양수분함량 측정 센서의 성능 검증

  • Kim, Ki-Deog (Highland Agriculture Research Institute, National Institute of Crop Science) ;
  • Suh, Jong-Taek (Highland Agriculture Research Institute, National Institute of Crop Science) ;
  • Yoo, Dong-Lim (Highland Agriculture Research Institute, National Institute of Crop Science) ;
  • Kim, Chang-Seok (Highland Agriculture Research Institute, National Institute of Crop Science) ;
  • Jee, Sam-Nyu (Highland Agriculture Research Institute, National Institute of Crop Science) ;
  • Hong, Soon-Choon (Highland Agriculture Research Institute, National Institute of Crop Science) ;
  • Kim, Sung Kyeom (Department of Horticultural Science, College of Agricultural & Life Science, Kyungpook National University)
  • 김기덕 (농촌진흥청 국립식량과학원 고령지농업연구소) ;
  • 서종택 (농촌진흥청 국립식량과학원 고령지농업연구소) ;
  • 유동림 (농촌진흥청 국립식량과학원 고령지농업연구소) ;
  • 김창석 (농촌진흥청 국립식량과학원 고령지농업연구소) ;
  • 지삼녀 (농촌진흥청 국립식량과학원 고령지농업연구소) ;
  • 홍순춘 (농촌진흥청 국립식량과학원 고령지농업연구소) ;
  • 김성겸 (경북대학교 농업생명과학대학 원예과학과)
  • Received : 2021.02.25
  • Accepted : 2021.04.23
  • Published : 2021.04.30

Abstract

A simple soil moisture measurement method based on the weight of soil cone was developed. Soil cone is a conical porous ceramic cup filled with soil. In the three soil samples (fine sandy soil, silt loam, and sandy loam), the soil moisture content by core method and FDR (Frequency domain reflectometry) method showed a linear relationship with the regression coefficients of 0.92 - 0.98 and 0.97 - 0.99, respectively. The volumetric moisture content of the soil inside the soil cone to the soil cone water weight and the FDR sensor value showed a relationship with regression coefficient of 0.96 and 0.97, respectively. The relationship between the soil cone weight and the FDR sensor value (r2 = 0.99, p < 0.001) was highly significant. Therefore, it was possible to measure soil moisture content by weighing of soil cone.

토양 콘의 무게를 기반으로 한 간단한 토양 수분 측정 방법이 개발되었다. 토양 콘은 토양으로 채워진 원추형 다공성 세라믹 컵이다. 세 가지 토양 샘플에서 코어 방법과 FDR(Frequency Domain reflectometry) 방법에 의한 토양 수분 함량은 직선 회귀식의 결정계수가 각각 0.92-0.98 및 0.97-0.99였으며, 선형 관계였다. 토양 세라믹 콘 내부 토양의 체적 수분 함량과 콘 내부 토양 수분 중량 및 FDR의 센서 값의 회귀 결과 결정계수가 각각 0.96 및 0.97였다. 토양 콘 중량과 FDR 센서 값(r2 = 0.99, p < 0.001) 사이는 높은 유의한 상관관계가 있었다. 따라서 토양 콘의 무게를 측정하여 토양 수분 함량을 측정할 수 있었다.

Keywords

Acknowledgement

본 성과물은 농촌진흥청 연구사업(세부과제번호: PJ01385901)의 지원에 의해 이루어진 것임.

References

  1. Campbell D.J., and J.K. Henshall 1991, Bulk density. pp 329-366. In K.A. Smith and C.E. Mullins (ed.) Soil analysis. Physical methods. Marcel Dekker, New York.
  2. Campbell J.E. 1990, Dielectric properties and influence of conductivity in soils at one to fifty megahertz. soil Sci. Soc. Am. J 54:332-341. doi:10.2136/sssaj1990.03615995005400020006x
  3. Eom K.C., K.S. Ryu, and K.T. Um 1988, Comparison of the measurement methods of soil water content by error analysis. Korean J. Soil Sci. Fert. 21:367-372. (in Korean)
  4. Fouad Y., D. Michot, Z. Thomas, R.V. Rossel 2014, Soil water content estimation using visible and near infrared spectroscopy. p. 588. In Proceedings of the 20th World Congress of Soil Science, Jeju, Korea. http://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE02447691
  5. Hur S.O., S.K. Ha, and J.G. Kim 2009, Verificaion of TDR and FDR sensors for volumetric soil water content measurement in sandy loam soil. Korean J. Soil Sci. Fert 42:110-116. (in Korean)
  6. Jung I.K., Y.C. Chang, K.B. Kim, Y.I. Kim, and S.O. Chung 2007, Development of a digital soil tensiometers using porous ceramic cups. J. of biosystems Eng 32:448-454. doi:10.5307/JBE.2007.32.6.448 (in Korean)
  7. Kim C.K., and G.C Lee 1996, New agriculture hydraulics. Hyangmunsa, Seoul, Korea.
  8. Kim K.B., S.C. Kim, D.S. Joo, and D.J. Yoon 2003, Precision measurement of water content in soil using dual RF impedance changes. J. Korean Soc. Agric. Machinery 28:369-376. (in Korean)
  9. Lim S.E., and J.Y. Kim 2020, Comparison of soil moisture sensor calibrations for various soil types for strawberry cultivation. p. 28. In Proceeding of the Society of People, Plants, and Environment 2020(1). Muan, Korea.
  10. Lim S.U. 1984, Soil science theory. Munundang, pp 102-103.
  11. Novak V., and H. Hlavacikova 2019, Soil water content and its measurement. In Applied soil hydrology. Theory and applications of transport in porous media 32:49-61. Springer, Cham.
  12. Oh Y.T., S.S. Oh, K.C. Song, J.S. Shin, and J.N. Im 1998, application of dielectric sensor for soil moisture measurement. Korean J. Soil Sci. Fert 31:85-94. (in Korean)
  13. Ok J.H., K.H. Han, Y.J. Lee, Y.S. Zhang, H.R. Cho, S.A. Hwang, S.S. Kim, J.H. Lee, and D.J. Kim 2018, Water balance for Chinese cabbage in spring season with different upland soils evaluated using weighable lysimeters. Korean J. Soil Sci. Fert 51:555-563. (in Korean) doi:10.7745/KJSSF.2018.51.4.555
  14. R. Evett S.R., R.C. Schwartz, J.J. Casanova.a, and L.K. Heng 2012, Soil water sensing for water balance, ET and WUE. Agricultural Water Management 104:1-9. doi:10.1016/j.agwat.2011.12.002
  15. Topp G.C., and J.L. Davis 1985, Measurement of soil water content using time-domain reflectometry in field evaluation. Soil Sci. Soc. Am. J 49: 19-24. doi:10.2136/sssaj1985.03615995004900010003x
  16. Wang M., X. Li, L. Chen, S. Hou, G. Wu, and Z. Deng 2020, A modified soil water content measurement technique using actively heated fiber optic sensor. J. Rock Mech. Geotech. Eng 12:608-619. doi:10.1016/j.jrmge.2019.11.003