DOI QR코드

DOI QR Code

Design of Facial Image Data Collection System for Heart Rate Measurement

심박수 측정을 위한 안면 얼굴 영상 데이터 수집 시스템 설계

  • Jang, Seung-Ju (Department of Computer Engineering, Dong-Eui University)
  • Received : 2021.05.03
  • Accepted : 2021.06.19
  • Published : 2021.07.31

Abstract

In this paper, we design a facial facial image data collection system for heart rate measurement using a web camera. The design content of this paper is a function of collecting user face image information using a web camera and measuring heart rate using the user's face image information. There is a possibility that an error may occur due to non-contact heart rate measurement using a web camera. Therefore, in this paper, it is to be used for correcting heart rate program errors through classification of data in cases of error and normal. The data in case of error can be used for the purpose of reducing the error. Experiments were conducted on the proposed ideas and designed in this paper. As a result of the experiment, it was confirmed that it operates normally.

본 논문은 심박수 측정을 위한 안면 얼굴 영상 데이터 수집 시스템을 설계한다. 본 논문의 설계 내용은 웹 카메라를 이용하여 사용자 얼굴 영상 정보들을 수집하고, 수집된 사용자 얼굴 영상 정보들을 이용하여 심박수를 측정하는 기능이다. 웹 카메라를 이용한 비접촉식 심박수 측정으로 인하여 오차가 발생할 가능성이 있다. 따라서 본 논문에서는 심박수 측정시 얼굴 영상 데이터 분류를 통해서 오차가 발생한 경우와 정상적인 경우를 구별하여 심박수 프로그램 오차 수정에 이용할 수 있도록 하고자 한다. 오차가 발생된 경우의 자료를 이용하여 오차를 줄이기 위한 목적으로 사용할 수 있도록 한다. 본 논문에서 제안하고 설계한 내용에 대해서 실험을 수행하였다. 실험 결과 본 논문에서 설계한 내용이 정상적으로 동작됨을 확인할 수 있었다.

Keywords

Acknowledgement

This Work was supported by Dong-eui University Foundation Grant(2020)

References

  1. M. Z. Poh, D. J. McDuff, and R. W. Picard, "Non-contact, automated cardiac pulse measurements using video imaging and blind source separation," Optics Express, vol. 18, no. 10, pp. 1-13, May. 2010.
  2. M, Garbey, N. Sun, A. Merla, and I. Pavlidis, "Contact-free measurement of cardiac pulse based on the analysis of thermal imagery," IEEE Transactions on Biomedical Engineering, vol. 54, no. 8, pp. 1418-1426, Jul. 2007. https://doi.org/10.1109/TBME.2007.891930
  3. D. Shao, C. Liu, and F. Tsow, "Noncontact Physiological Measurement Using a Camera : A Technical Review and Future Directions," ACS sensors, vol. 21, no. 7, pp. 321-334, Dec. 2020.
  4. E. Moya-Albor, J. Brieva, H. Ponce, and L. MartinezVillasenor, "A non-contact heart rate estimation method using video magnification and neural networks," IEEE Instrumentation & Measurement Magazine, vol. 23, no. 4, pp. 56-62, Jun. 2020.
  5. J. R. Maestre-Rendon, T. A. Rivera-Roman, A. A. Fernandez-Jaramillo, N. E. G. Paredes, and J. J. S. Olmedo, "A non-contact photoplethysmography technique for the estimation of heart rate via smartphone," Applied Sciences Basel, vol. 10, no. 154, pp. 1-11, Dec. 2019.
  6. N. Ibrahim, M. Tomari, and W. Zakaria, "Analysis of minimum face video duration and the effect of video compression to image-based non-contact heart rate monitoring system," Bulletin of Electrical Engineering Informatics, vol. 9, no. 1, pp. 1-11, Dec. 2019. https://doi.org/10.11591/eei.v9i1.1486
  7. M. Lewandowska, J. Ruminski, and T. Kocejko, "Measuring Pulse Rate with a Webcam - a Non-contact Method for Evaluating Cardiac Activity," 2011 Federated Conference on Computer Science and Information Systems (FedCSIS), Poland, pp. 405-410, 2011.
  8. D. Lee, S. Hwang, M. Kim, S. Park, and M. Whang, "Real-time Measurement System of Heartbeat based on Facial RGB," Extended Abstracts of HCI KOREA, pp. 85-86, 2014.
  9. D. J. McDuff, E. B. Blackford, and J. R. Estepp, "The impact of video compression on remote cardiac pulse measurement using imaging photoplethysmography," 2017 12th IEEE International Conference on Automatic Face & Gesture Recognition (FG 2017), Washington DC, pp. 1- 8, 2017.
  10. H. Rahman, M. U. Ahmed, S. Begum, and P. Funk, "Real-time Heart Rate Monitoring From Facial RGB Color Video Using Webcam," The 29th Annual Workshop of the Swedish Artificial Intelligence Society (SAIS), pp. 1-8, Jun. 2016.