DOI QR코드

DOI QR Code

Durability Assessment by Structural and Fatigue Analysis of Flow Control Valves (FCVs) for Hydrogen Refueling Stations

수소 충전소용 유량제어밸브(FCV)의 구조 및 피로해석을 통한 내구 성능 평가

  • CHOI, INHO (Department of Mechanical Engineering, Gachon University) ;
  • HA, TAE IL (HIFLUX) ;
  • KIM, HAN SANG (Department of Mechanical Engineering, Gachon University)
  • Received : 2022.06.20
  • Accepted : 2022.06.27
  • Published : 2022.06.30

Abstract

This study was conducted to develop a domestic product for a flow control valve for a hydrogen refueling station, and a domestic prototype was manufactured and the durability performance evaluation was conducted through comparison with an imported products. The stress generated by the internal pressure was checked and safety was confirmed using a commercial structural analysis program, ABAQUS, in accordance with the withstand pressure test standards. In addition, after identifying the weak areas the fatigue life was predicted through a commercial software, fe-safe. This fatigue analysis showed that the hydrogen gas repeated test criteria were satisfied.

Keywords

Acknowledgement

이 논문은 2019년도 가천대학교 교내연구비 지원에 의한 결과이다(GCU-2019-0710). 본 연구는 산업통상자원부(MOTIE)와 한국에너지기술평가원(KETEP)의 지원을 받아 연구한 과제이다(No. 20203010040010).

References

  1. S. H. Kang, S. J. Choi, and J. W. Kim, "Analysis of the world energy status and hydrogen energy technology R&D of foreign countries", Trans Korean Hydrogen New Energy Soc, Vol. 18, No. 2, 2007, pp. 216-223. Retrieved from http://manu.hydrogen.or.kr/archive/archiveViewContents.php.
  2. B. W. Kang. T. H. Kim, T. H. Lee, "Analysis of costs for a hydrogen refueling station in Korea", Trans Korean Hydrogen New Energy Soc, Vol. 27, No. 3, 2016, pp. 256-263, doi: https://doi.org/10.7316/KHNES.2016.27.3.256.
  3. Ministry of Trade, Industry and Energy, "Joint by related ministries, 「Hydrogen infrastructure and charging station construction plan」 announced", Ministry of Trade, Industry and Energy, 2019. Retrieved from http://www.motie.go.kr/motie/gov_info/gov_openinfo/sajun/bbs/bbsView.do?bbs_seq_n=162215&bbs_cd_n=81.
  4. C. K. Kim, S. M. Lee, and C. M. Jang, "Numerical evaluation of flow nature at the downstream of a ball valve used for gas pipelines with valve opening rates", Trans Korean Hydrogen New Energy Soc, Vol. 29, No. 4, 2018, pp. 370-377, doi: https://doi.org/10.7316/KHNES.2018.29.4.370.
  5. Fujikin Carp Group, "Valves & fittings for ultra high-pressure hydrogen gas", Fujikin Carp Group, 2020, pp. 4-26. Retrieved from https://www.fujikin.co.jp/support/pdf/10003_hyd_eng.pdf.
  6. Ministry of Trade, Industry and Energy, "Gaseous hydrogen-fueling stations part3: valves. KS B ISO 19880-3", Ministry of Trade, Industry and Energy, 2018, pp. 7. Retrieved from https://e-ks.kr/streamdocs/view/sd;streamdocsId=72059206369487874.
  7. A. Unt, H. Piili, M. Hirvimaki, M. Manninen, and A. Salminen, "Laser scribing of stainless steel with and without work media", ICALEO, 2010, pp. 1012-1021, doi: https://doi.org/10.2351/1.5061932.
  8. P. Eriksson, "Evaluation of mechanical and microstructural properties for laser powderbed fusion 316L", Uppsala Universitet, 2018, pp. 3-34, 2018. Retrieved from https://www.divaportal.org/smash/get/diva2:1231504/FULLTEXT01.pdf.
  9. S. Y. Kim and K. W. Nam, "Failure criterion of straight pipe with outer local wall thinning under internal pressure" Journal of Power Systems Engineering, Vol. 18, No. 1, 2014, pp. 76-83, doi: https://doi.org/10.9726/kspse.2014.18.1.076.
  10. Y. Shu, L. Ke, J. Su, and F. Shen. "Experimental studies on fretting wear behavior of PVDF piezoelectric thin films", Materials, Vol. 14, No. 4, 2021, pp. 734, doi: https://doi.org/10.3390/ma14040734.
  11. I. M. G. Karohika, I. N. G. Antara, and I. M. D. Budiana,"Influence of dies type for gasket forming shape", Mater. Sci. Eng., Vol. 539, 2019. pp. 012019, doi: https://doi.org/10.1088/1757-899X/539/1/012019.
  12. HIFLUX, "High pressure valves & fittings", pp. 3655. Retrieved from http://m.hiflux.com/pdf/tube_nipple_kr.pdf.
  13. KS B ISO 19880-3, "Gaseous hydrogen-fueling stations-part3:valves", pp. 13-14, 2018. Retrieved from https://e-ks.kr/streamdocs/view/sd;streamdocsId=72059206369487874.
  14. M. A. A. Khan and A. K. Sheikh, "Simulation-based mould design, life prediction and reliability assessment of a valve body", Int. J. Simul. Modelling, Vol. 20, No. 2, 2021, pp. 219-230, doi: https://doi.org/10.2507/IJSIMM20-2-543.
  15. X. Hong, G. Xiao, W. Haoyu, L. Xing, and W. Sixing, "Fatigue damage analysis and life prediction of e-clip in railway fasteners based on ABAQUS and FE-SAFE", Advances in Mechanical Engineering, Vol. 10, No. 3, 2018, pp. 1-12, doi: https://doi.org/10.1177/1687814018767249.
  16. Dassault Systemes Simulia Corp, "fe-safe 2021 fe-safe USER GUIDE", Dassault Systemes Simulia Corp, 2021. Retrieved from https://www.caecis.com/wpcontent/uploads/2020/12/FesafeUser.pdf.
  17. Z. Zhang, A. Li, Y. Wang, Q. Lin, and X. Chen, "Low-cycle fatigue behavior and life prediction of fine-grained 316LN austenitic stainless steel", Journal of Materials Research, Vol. 35, 2020, pp. 3180-3191, doi: https://doi.org/10.1557/jmr.2020.322.