The Frost and Defrost Performances of Fin-and-Tube Exchangers with Different Surface Characteristics

표면특성이 다른 두 핀-관 열교환기의 착상 및 제상 성능

  • 신종민 (LG전자 디지털 어플라이언스 사업본부 연구소) ;
  • 최봉준 (LG전자 디지털 어플라이언스 사업본부 연구소)
  • Published : 2002.06.01

Abstract

The effects of different surface hydrophilicity on frosting and defrosting characteristic were experimentally investigated. Mass of frost and water hold-up was measured. Results showed that no significant difference in the frost mass was found between the two different surfaces while the water hold-up of heat exchanger court be reduced by the enhancement of surface hydrophilicity. Also, the defrosting efficiency m hydrophilic surface was improved by 76%. It was expected that hydrophilic heat exchanger could provide the improvements in both thermal-hydraulic performances and system reliability during frost/defrost operating in refrigeration systems.

Keywords

References

  1. Refrigerating Engineering v.65 no.2 How frost formation on coils affects refrigeration systems Stoecker, W. F.
  2. Bulletin of JSME v.29 no.251 A study of extended surface heat exchanger with frosting Aoki, K.;Hattori, M.;Itoh, T. https://doi.org/10.1299/jsme1958.29.1499
  3. Thermal Science & Engineering v.6 no.1 Characteristics estimation of heat exchanger operating with frosting Aoki, K;Sawada, M.
  4. ASHRAE Transactions v.97 no.2 A parametric study of the factors governing the rate of frost accumulation on domestic refrigerator-freezer finned-tube evaporators coils Rite, R. W.;Crawford, R. R.
  5. Proceedings of the International Conference on Heat Exchangers for Sustainable Development Condensate Drainage Characteristics of Plate Fin-and-Tube Heat Exchanger Ha, S. C.;Kim, C. H.;Ahn, S. P.;Dreitser, G. A.
  6. Proceedings of Compact Heat Exchangers and Enhancement of Technology for the Process Industries Hydraulic Performance of Wet Fin-and-Tube Heat Exchanger for Various Wettability Surfaces Ha, S. C.;Kim, C. H.;Ahn, S. P.;Dreitser, G. A.
  7. Proceedings of the 9th International Sympoisum on Flow Visualization no.413 A Study of Water Hold-up of Two Surfaces Having Different Hydro-Characteristics Shin, J. M.;Kim, J. B.;Kim, C. H.;Ha, S. C.
  8. Porceedings of the SAREK v.10 no.6 The effect of water contact angles of the fin surfaces of the fin-and-tube heat exchangers on the water hod-up Shin, J. M.;Lee, N. G.;Han, S. J.;Ha, S. C.
  9. Journal of Material Research v.10 no.6 Improving Wettability of Polycarbonate(PC) and Adhesion with Aluminum by Ar+ Ion Irradiation Koh, S.;Han, S.;Song, S.;Choi, W.;Jung, H. https://doi.org/10.1557/JMR.1995.2390
  10. ASME Journal of Fluids Engineering v.107 ASME Measurement Uncertainty Abernathy, R. B.;Benedict, R. P.;Dowdell, R. B. https://doi.org/10.1115/1.3242450
  11. International Journal of Refrigeration The effect of Hydrophilicity on Condensation over Various types of Fin-and-Tube Heat Exchangers Shin, J.;Ha, S.
  12. Journal of HVAC&R v.12 no.1 The effect of surface contact angle of the behavior of frost formation in a fin-tube heat exchanger Lee, K. S.;Jee, S.;Lee, D. W.
  13. Journal of HVAC&R v.10 no.6 Anexperimental study of behavior of defrosting on the fin-tube heat exchanger Lee, K. S.;Kim, G. W.;Jee, S.