DOI QR코드

DOI QR Code

Lens Design of the Eyepiece Combined with the Accommodation-dependent Navarro Eye at an On-axis Point

  • Choi, Ka-Ul (Department of Ophthalmic Optics, Baekseok Culture University) ;
  • Song, Seok-Ho (Department of Physics, Hanyang University) ;
  • Kim, Sang-Gee (Department of Optometry and Vision Science, Dongnam Health College)
  • Received : 2009.12.14
  • Accepted : 2010.02.23
  • Published : 2010.03.25

Abstract

We introduce a new method for lens design that combines an eyepiece with the finite model eye, to make a corrected version of the accommodation-dependent Navarro eye. The optical system that we designed, which includes a human eye, takes into account the aberration of the eye and increases the performance of the image in the retina. In the design results, for the optimized eyepiece combined with the corrected Navarro eye, visual acuity is 1.40. Compared with the existing method of eyepiece design using inverse ray tracing with the corrected Navarro eye, MTF value was recorded as 0.079 to 0.283 at 160 lp/mm and visual performance was improved.

Keywords

References

  1. J. T. Schwiegerling, “Performance prediction using schematic eye models,” Ph. D. Thesis, The University of Arizona (1995).
  2. H.-L. Liou and N. A. Brennan, “Anatomically accurate, finite model eye for optical modeling,” J. Opt. Soc. Am. A 14, 1684-1695 (1997). https://doi.org/10.1364/JOSAA.14.001684
  3. R. Navarro, J. Santamaria, and J. Bescos, “Accommodation dependent model of the human eye with aspherics,” J. Opt. Soc. Am. A 2, 1273-1281 (1985). https://doi.org/10.1364/JOSAA.2.001273
  4. M. D. Missig and G. M. Morris, “Diffractive optics applied to eyepiece design,” Appl. Opt. 34, 2452-2461 (1995). https://doi.org/10.1364/AO.34.002452
  5. Y. G. Ha and J. Rolland, “Optical assessment of head-mounted displays in visual space,” Appl. Opt. 41, 5282-5289 (2002). https://doi.org/10.1364/AO.41.005282
  6. K. U. Choi, S. H. Song, and S. G. Kim, “Visual performances of the corrected Navarro accommodation-dependent finite model eye,” Hankook Kwanghak Hoeji (Korean J. Opt. Photon.) 18, 337-344 (2007). https://doi.org/10.3807/HKH.2007.18.5.337
  7. G. Westheimer, “Image quality in the human eye,” Opt. Acta. 17, 641-658 (1970). https://doi.org/10.1080/713818355
  8. F. W. Campbell and D. G. Green, “Optical and retinal factors affecting visual resolution,” J. Physiol. 181, 576-593 (1965). https://doi.org/10.1113/jphysiol.1965.sp007784
  9. C. S. Rim, S. S. Lee, C. S. Park, and J. S. Kim, “Optical design of a zoom eyepiece,” Hankook Kwanghak Hoeji (Korean J. Opt. Photon.) 5, 356-363 (1994).
  10. B. H. Walker, Optical Design for Visual Systems (SPIEInternational Society for Optical Engineering, Bellingham, Washington, USA, 2000).
  11. T. Buehren and M. J. Collins, “Accommodation stimulusresponse function and retinal image quality,” Vision Research 46, 1633-1645 (2006). https://doi.org/10.1016/j.visres.2005.06.009
  12. S. G. Kim and S. C. Park, “Prediction of visual performance using contrast sensitivity function and modulation transfer function,” Hankook Kwanghak Hoeji (Korean J. Opt. Photon.) 15, 461-468 (2004). https://doi.org/10.3807/KJOP.2004.15.5.461

Cited by

  1. Improving transmission efficiency of Cassegrain antenna vol.126, pp.7-8, 2015, https://doi.org/10.1016/j.ijleo.2015.02.068