Abstract

In large-scale production of hydrogen, a PHE (Process Heat Exchanger) is a key component because the heat required to carry out the Sulfur-Iodine chemical reaction that yields hydrogen is transferred from a VHTR (Very High Temperature Reactor) by the PHE. Korea Atomic Energy Research Institute established a helium gas loop for conducting performance test of components that are used in the VHTR. In this study, as a part of high-temperature structural-integrity evaluation of a designed PHE prototype that is scheduled to be tested in the helium gas loop, we carried out high-temperature structural-analysis modeling, thermal analysis, and thermal-expansion analysis for the designed PHE prototype. An appropriate constraint condition is proposed at the end of the in-flow and out-flow pipelines of the primary and secondary coolants and the proposed constraint condition will be applied to the design of the performance-test loop setup for the designed PHE prototype.

초고온가스로에서 생성된 $950^{\circ}C$ 정도의 초고온 열을 이용하여 수소를 경제적이며 또한 대량으로 생산하기 위한 시스템이 원자력수소생산시스템이며, 공정열교환기는 초고온 열과 황-요오드 공정을 통해 수소를 생산하는 원자력수소생산시스템에서의 핵심 기기이다. 한국원자력연구원에서는 초고온가스로에 사용될 기기에 대한 성능시험을 위해 최대 작동 설계온도 $1000^{\circ}C$인 헬륨가스루프를 구축하고 있으며 공정열교환기를 설계하였다. 본 연구에서는 구축중인 헬륨가스루프에서 성능시험을 수행할 예정으로 설계된 공정열교환기에 대한 고온 구조건전성을 미리 평가하기 위한 작업의 일환으로 고온구조해석 모델링, 열해석 및 열팽창 해석을 수행한 결과를 정리한 것이다. 해석결과를 이용하여 설계된 공정열교환기의 구조건전성을 유지하기 위한 1 차 및 2 차 열매체의 유입/유출 파이프라인에서의 적절한 구속조건을 결정하였으며 이를 향후 제작될 공정열교환기 시제품의 성능시험 장치 설계에 반영할 것이다.

Keywords

References

  1. US DOE, 2009, Financial Assistance Funding Opportunity Announcement, NGNP Program.
  2. AREVA, 2007, NGNP with Hydrogen Production Pre-conceptual Design Studies Report, Doc. No. 1209052076-000.
  3. Idaho National Laboratory, 2007, NGNP Preconceptual Design Report, INL/EXT-07-12967.
  4. Westinghouse, 2007, NGNP and Hydrogen Production Pre-conceptual Design Report, NGNPESP- RPT-001, Rev 1.
  5. Chang, J. H, et al., 2007, "A Study of a Nuclear Hydrogen Production Demonstration Plant," Nuclear Engineering and Technology, Vol. 39, No. 2, pp. 111- 122. https://doi.org/10.5516/NET.2007.39.2.111
  6. Kim, Y. W., et al. 2009, Development of Essential Technology for VHTR, Final report KAERI/RR- 2992/2008.
  7. Song, K. N., 2009, "Analysis Modeling of a Small PHE for Thermal/Structural Analysis," Calculation note No. NHDD-KT-CA-10-001 Rev.00.
  8. Kim, Y. W. et al., 2006 "High Temperature and High Pressure Corrosion Resistant Process Heat Exchanger for a Nuclear Hydrogen Production System," R.O.K Patent submitted 10-2006-0124726.
  9. Song, K. N. et al., 2010, "High-Temperature Structural Analysis Model on the Process Heat Exchanger for Nuclear Hydrogen System," Proc. of KSME-JSME Joint Symposium 2010 on Computational Mechanics and Computer-aided Engineering, pp. 100-101.
  10. I-DEAS/TMG ver 6.1, 2009.
  11. Hastelloy-X Alloy website, www.haynesintl.com.
  12. ABAQUS ver. 6.8, 2009.
  13. Draft Alloy 617 Code Case, Case N-47-28, 1988, Task Force Very High Temperature Design, ASME.

Cited by

  1. High-Temperature Structural Analysis of a Small-Scale PHE Prototype under the Test Condition of a Small-Scale Gas Loop vol.2012, pp.1687-6083, 2012, https://doi.org/10.1155/2012/312080
  2. High-Temperature Structural Analysis Model of the Process Heat Exchanger for Helium Gas Loop (II) vol.34, pp.10, 2010, https://doi.org/10.3795/KSME-A.2010.34.10.1455
  3. High-Temperature Structural Analysis of a Small-Scale Prototype of a Process Heat Exchanger (IV) - Macroscopic High-Temperature Elastic-Plastic Analysis - vol.35, pp.10, 2011, https://doi.org/10.3795/KSME-A.2011.35.10.1249
  4. Macroscopic High-Temperature Structural Analysis Model for a Small-Scale PCHE Prototype (I) vol.35, pp.11, 2011, https://doi.org/10.3795/KSME-A.2011.35.11.1499
  5. High-temperature Structural Analysis of Small-scale Prototype of Process Heat Exchanger (III) vol.35, pp.2, 2011, https://doi.org/10.3795/KSME-A.2011.35.2.191
  6. High-Temperature Structural Analysis of a Medium-Scale Process Heat Exchanger Prototype vol.36, pp.10, 2012, https://doi.org/10.3795/KSME-A.2012.36.10.1283