DOI QR코드

DOI QR Code

Development of Seismic Retrofit Devices for Building Structures

  • Kim, Jinkoo (Department of Civil & Architectural Engineering, Sungkyunkwan University)
  • Published : 2019.09.01

Abstract

In this paper passive seismic retrofit devices for building structures developed by the author in recent years are introduced. The proposed damping devices were developed by slightly modifying the configuration of conventional devices and enhancing their effectiveness. First a seismic retrofit system consisting of a pin-jointed steel frame and rotational friction dampers installed at each corner of the steel frame was developed. Then two types of steel slit dampers were developed; box-type slit damper and multi-slit damper. In addition, hybrid dampers were developed by combining a slit damper and a friction damper connected in parallel. Finally a self-centering system was developed by using preloaded tendons and viscous dampers connected in series. For each retrofit system developed, an appropriate analytical model was developed, and the seismic performance was verified by loading test and earthquake analysis of case study structures. The experimental and analysis results show that the proposed systems can be used efficiently to enhance the seismic performance of building structures.

Keywords

References

  1. Belleri, A., Marini, A., Riva, P., and Nascimbene, R. (2017). Dissipating and re-centring devices for portal-frame precast structures. Engineering Structures, Elsevier, 150, 736-745. https://doi.org/10.1016/j.engstruct.2017.07.072
  2. Bergman DM, Goel SC. Evaluation of cyclic testing of steel plate devices for added damping and stiffness. Report no. UMCE87-10. The University of Michigan; 1987.
  3. Chan R.W.K., Albermani F. Experimental study of slit damper for passive energy dissipation. Engineering Structures. 2008; 30(4):1058-66. https://doi.org/10.1016/j.engstruct.2007.07.005
  4. Chen CS, Chen KC, Pong WS, Tsai CS. Parametric Study for Buildings with Combined Displacement Dependent and Velocity Dependent Energy Dissipation Devices. Structural Engineering and Mechanics 2002; 14(1):85-98. https://doi.org/10.12989/sem.2002.14.1.085
  5. Chou CC., Tsai WJ., Chung PT. (2016). Development and validation tests of a dual-core self-centering sandwiched buckling-restrained brace (SC-SBRB) for seismic resistance. Journal of Structural Engineering, 121, 30-41. https://doi.org/10.1016/j.engstruct.2016.04.015
  6. Christopoulos, C., Tremblay, R., Kim, H. J., & Lacerte, M. (2008). Self-centering energy dissipative bracing system for the seismic resistance of structures: development and validation. Journal of Structural Engineering, 134(1), 96-107. https://doi.org/10.1061/(ASCE)0733-9445(2008)134:1(96)
  7. Dolce, M., & Cardone, D. (2006). Theoretical and experi-mental studies for the application of shape memory alloys in civil engineering. Journal of engineering materials and technology, 128(3), 302-311. https://doi.org/10.1115/1.2203106
  8. Dyanati, M., Huang, Q., & Roke, D. A. (2014). Structural and nonstructural performance evaluation of self-centering,concentrically braced frames under seismic loading. In Structures Congress 2014, 2393-2404.
  9. Eatherton, M. R., Ma, X., Krawinkler, H., Mar, D., Billington,S., Hajjar, J. F., & Deierlein, G. G. (2014). Design conceptsfor controlled rocking of self-centering steel-braced frames. Journal of Structural Engineering, 140(11).
  10. Ingalkar, R. S. (2014). Rehabilitation of Buildings and Bridgesby Using Shape Memory Alloys (SMA). International Journal of Civil Engineering Research, 5(2), 163-168.
  11. Javidan MM, Kim J (2019). Seismic Retrofit of Soft-First Story Structures Using Rotational Friction Dampers, Journal of Structural Eng, Accepted for publication.
  12. Lee J., Kim J (2015). Seismic performance evaluation of moment frames with slit-friction hybrid dampers. Earthquakesand Structures 9(6): 1291-1311. https://doi.org/10.12989/eas.2015.9.6.1291
  13. Lee J, Kang H, Kim J (2017). Seismic performance of steel plate slit-friction hybrid dampers, Journal of ConstructionalSteel Research 136: 128-139.
  14. Lee J., Kim J (2017). Development of box-shaped steel slit dampers for seismic retrofit of building structures, Eng-ineering structures 150: 934-946. https://doi.org/10.1016/j.engstruct.2017.07.082
  15. Marshall JD, Charney FA (2012). Seismic response of steel frame structures with hybrid passive control systems. Earthquake Engineering & Structural Dynamics 41(4): 715-733. https://doi.org/10.1002/eqe.1153
  16. Miller D. J., Fahnestock L. A., Eatherton, M. R. (2012). Development and experimental validation of a nickel-titanium shape memory alloy self-centering buckling-restrained brace. Engineering Structures, 40, 288-298. https://doi.org/10.1016/j.engstruct.2012.02.037
  17. Naeem, A., and Kim, J. (2018). Seismic retrofit of a framed structure using damped cable systems. Steel and Composite Structures, Techno-Press, 29(3), 287. https://doi.org/10.12989/SCS.2018.29.3.287
  18. Naeem A., NourEldin M., Kim, J.(2017). Seismic per-formance evaluation of a structure retrofitted using steel slit dampers with shape memory alloy bars. International Journal of Steel Structures, 17(4), 1627-1638. https://doi.org/10.1007/s13296-017-1227-4
  19. Nour Eldin M, Kim JG, Kim J. (2018). Optimum distribution of steel slit-friction hybrid dampers based on life cycle cost, Steel and Composite Structures, 27(5), 633-646 https://doi.org/10.12989/SCS.2018.27.5.633
  20. Omika Y, Koshika K, Yamamoto Y, Kawano K, Shimizu K (2016). High-rise reinforced-concrete building incorporatingan oil damper in an outrigger frame and its vibration analysis, International Journal of Highrise Buildings, 5(1),43-50 https://doi.org/10.21022/IJHRB.2016.5.1.43
  21. Pekcan G., Mander JB., Chen SS. (2000). Balancing lateral loads using tendon-based supplemental damping system. Journal of structural engineering 126(8): 896-905. https://doi.org/10.1061/(ASCE)0733-9445(2000)126:8(896)
  22. Rahman MA., Sritharan S. (2007). Performance-based seismicevaluation of two five-story precast concrete hybrid frame buildings. Journal of Structural Engineering, 133(11), 1489-1500. https://doi.org/10.1061/(ASCE)0733-9445(2007)133:11(1489)
  23. Roke D., Jeffers B. (2012). Parametric study of self-centering concentrically-braced frame systems with friction-based energy dissipation. Proceeding of Behaviour of Steel Structures in Seismic Areas (STESSA), 691-696.
  24. Sorace S, Terenzi, G (2001). Non-linear dynamic modelling and design procedure of FV spring-dampers for base isolation. Engineering Structures 23(12): 1556-1567. https://doi.org/10.1016/S0141-0296(01)00063-3
  25. Sorace, S. and Terenzi, G. (2012). The damped cable system for seismic protection of frame structures. Part I: General concepts, testing, and modeling. Earthquake Engineering & Structural Dynamics 41(5): 915-928. https://doi.org/10.1002/eqe.1166